AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home Food Science Article
PDF (5.8 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

A Colorimetric/Fluorescent Dual Sensing System Based on the Enzyme-like Activity of Fluorescent Carbon Quantum Dots for Detection of Glucose

Huanan GUAN1,2 ( ), Mingyi ZHANG1, Dandan WANG1, Zhuzehui ZHANG2
College of Food Engineering, Harbin University of Commerce, Harbin 150076, China
School of Grain Science and Technology, Jiangsu University of Science and Technology, Zhenjiang 212100, China
Show Author Information

Abstract

A colorimetric/fluorescent dual-sensing assay for the detection of glucose was established based on the peroxidase-like activity of fluorescent carbon quantum dots derived from corncob. In the system, glucose oxidase was added to specifically catalyze the oxidation of glucose to produce H2O2, which was then reacted with 2,2’-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) under the catalysis of carbon quantum dots. Under optimized conditions, good linearity was observed between the absorbance (y) of the reaction system and glucose concentration (x) in the range of 0.001–0.5 mmol/L, which was fitted as follows: y = 10.907x + 0.6595, R2 = 0.9938, with a detection limit of 1.3055 μmol/L. Moreover, good linearity was observed between the difference in fluorescence intensity (y) and glucose concentration (x) in the range of 0.001–0.1 mmol/L, which was fitted as follows: y = 9172x + 4438, R2 = 0.9944, with a detection limit of 9.2497 nmol/L. The method was applied to the detection of glucose in four real samples, with good spiked recovery rates and precision, which indicated that corncob fluorescent carbon quantum dots have the potential for application as an enzyme mimic in the detection of glucose.

CLC number: TS207.3 Document code: A Article ID: 1002-6630(2024)24-0232-10

References

【1】
【1】
 
 
Food Science
Pages 232-241

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
GUAN H, ZHANG M, WANG D, et al. A Colorimetric/Fluorescent Dual Sensing System Based on the Enzyme-like Activity of Fluorescent Carbon Quantum Dots for Detection of Glucose. Food Science, 2024, 45(24): 232-241. https://doi.org/10.7506/spkx1002-6630-20240428-262

762

Views

5

Downloads

0

Crossref

1

Scopus

0

CSCD

Received: 28 April 2024
Published: 25 December 2024
© Beijing Academy of Food Sciences 2024.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).