AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home Food Science Article
PDF (2.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Determination of Flupyradifurone and Its Metabolites in Milk Using QuEChERS and Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry

Yanqiu CHEN1,2,3 , Hao LIN1,2,3, Quanwei XIAO1,2,3, Juan SONG1,2,3, Chuan LIU1,2,3 ( ), Qin DAI1,2,3 ( )
Chengdu Institute of Food Inspection, Chengdu 611130, China
Key Laboratory of Chemical Metrology and Applications on Nutrition and Health for State Market Regulation, Beijing 100029, China
Irradiation Preservation Technology Key Laboratory of Sichuan Province, Sichuan Institute of Atomic Energy, Chengdu 610101, China
Show Author Information

Abstract

A rapid method was developed for the simultaneous determination of flupyradifurone and its metabolites 6-chloronicotinic acid and difluoroacetic acid in milk using ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). A simple and efficient dispersive solid phase extraction method was used to purify milk samples, and the purification strategy was evaluated. After improved quick, easy, cheap, effective, rugged and safe (QuEChERS) treatment, 0.1% formic acid in acetonitrile was used as the mobile phase for chromatographic separation on a Shim-pack-GIST C18 column, and the detection was performed in the multiple reaction monitoring (MRM) mode. The external standard method with matrix standard curves was used for quantification. The results showed that under the optimal conditions, good linearity (determination coefficient greater than 0.996) was observed for flurofuranone, 6-chloronicotinic acid and difluoroacetic acid in the concentration ranges of 0.005–0.5, 0.005–0.5 and 0.025–2.5 mg/L, respectively. The average recoveries of flupyradifurone and its metabolites at three spiked concentrations varied from 70.2% to 97.6%, with relative standard deviations (RSDs) between 3.6% and 5.3%, and the limits of detection (LODs) ranged from 0.01 to 0.05 mg/kg, much lower than the national maximum residue limits. This method was characterized by high accuracy, high sensitivity, and good reproducibility. Therefore, it is suitable for large batches of milk samples, and can provide reliable technical support for the management of the pesticide flupyradifurone.

CLC number: O657.63 Document code: A Article ID: 1002-6630(2024)12-0285-07

References

【1】
【1】
 
 
Food Science
Pages 285-291

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
CHEN Y, LIN H, XIAO Q, et al. Determination of Flupyradifurone and Its Metabolites in Milk Using QuEChERS and Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry. Food Science, 2024, 45(12): 285-291. https://doi.org/10.7506/spkx1002-6630-20231116-120

866

Views

24

Downloads

0

Crossref

3

Scopus

0

CSCD

Received: 16 November 2023
Published: 25 June 2024
© Beijing Academy of Food Sciences 2024.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).