AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home Food Science Article
PDF (9.5 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Rapid Determination of Residues and Migration of Seven Isocyanate Compounds in Food Composite Packaging Bags by Ultra-high Performance Convergence Chromatography

Yue QIU1 , Genrong LI1, Qiuling YU1, Chaolan TAN1, Jiali LU1, Qing ZHANG2 ( )
Chongqing Academy of Metrology and Quality Inspection, Chongqing 401123, China
Jiulongpo District Center for Disease Control and Prevention, Chongqing 400039, China
Show Author Information

Abstract

An ultra-high performance convergence chromatography (UPC2) method was developed to rapidly determine the residues and migration of seven isocyanate compounds in food composite packaging bags. The separation was performed on an ACQUITY UPC2 HSS C18 SB column using gradient elution with a mobile phase consisting of CO2 and methanol. The column temperature was 40 ℃, and the system back pressure was 13.10 MPa. The analytes were detected by a photo diode array (PDA) detector and quantified by an external standard method. The results showed that under the optimal conditions, baseline separation of the seven isocyanate compounds could be achieved within 2 min. The detection limits were in the range of 1.0-3.0 μg/kg, and the quantitation limits were in the ranged from 5.0 to 10.0 μg/kg. At spiked levels of 10,125 and 625 μg/kg, the recoveries of the isocyanate compounds ranged from 85.1% to 108.4%, and the relative standard deviations (RSDs) ranged from 0.7% to 6.5%. The developed method was used to determine 40 batches of food composite packaging bag samples. Isocyanate compounds residues were found in 7 batches, among which the contents of TDI and DPI residues were relatively high, but no isocyanates were found to migrate from these positive samples. The establishment of this method can provide technical support for the determination of the residues and migration of isocyanate compounds in food composite packaging bags.

CLC number: O657.99 Document code: A Article ID: 1002-6630(2024)11-0285-08

References

【1】
【1】
 
 
Food Science
Pages 285-292

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
QIU Y, LI G, YU Q, et al. Rapid Determination of Residues and Migration of Seven Isocyanate Compounds in Food Composite Packaging Bags by Ultra-high Performance Convergence Chromatography. Food Science, 2024, 45(11): 285-292. https://doi.org/10.7506/spkx1002-6630-20231010-068

571

Views

7

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 10 October 2023
Published: 15 June 2024
© Beijing Academy of Food Sciences 2024.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).