AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home Food Science Article
PDF (6.7 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

A Rapid Detection Method for Freshness of Frozen Crayfish Based on Near-Infrared Spectroscopy

Ke ZHAN1 Jiwang CHEN1,2,3 ( )Yan XU1Yangfan NI4Yan LIU1,2,3Shengbi ZOU3
College of Food Science and Engineering, Wuhan Polytechnic University, Wuhan 430023, China
Hubei Key Laboratory for Processing and Transformation of Agricultural Products (Wuhan Polytechnic University), Wuhan 430023, China
National Research & Development Branch Center for Crayfish Processing (Qianjiang), Qianjiang 433100, China
Wuhan Agricultural Inspection Center, Wuhan 430016, China
Show Author Information

Abstract

To establish a model based on near-infrared (NIR) spectra for quickly detecting the freshness of frozen crayfish, NIR spectra of thawed crayfish (tail, meat, and mince) were collected, and data were pretreated by first derivative, multiple scattering correction, wavelet transform (WT), or standard normal transform. The original and pretreated spectral data were correlated to total volatile basic nitrogen (TVB-N) contents using partial least squares (PLS) or convolutional neural network (CNN), and different quantitative prediction models were established and compared. The best model was selected to investigate its accuracy and applicability. The results showed that pretreatment methods had a significant influence on the accuracy of the model, and the CNN model established after spectral preprocessing had a better ability to predict the TVB-N content of crayfish compared with the PLS model. The CNN model based on the WT pretreated spectra of crayfish meat had the highest prediction accuracy for the validation set with correlation coefficients of 0.97 and 0.96, and root mean square errors of 1.26 and 0.93 mg/100 g for the calibration set and validation set, respectively. Moreover, the accuracy, precision, and sensitivity of the NIR method were within reasonable limits, and it had good figures of merit. According to the requirements of fast operation, accurate results, and low damage in practice, the WT-CNN-crayfish meat model was determined as the optimal model for predicting the TVB-N content in frozen crayfish. These results suggested that the WT-CNN-crayfish meat model have a great potential for predicting the TVB-N content and rapidly evaluating the freshness of frozen crayfish.

CLC number: TS254.7 Document code: A Article ID: 1002-6630(2024)02-0299-09

References

【1】
【1】
 
 
Food Science
Pages 299-307

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHAN K, CHEN J, XU Y, et al. A Rapid Detection Method for Freshness of Frozen Crayfish Based on Near-Infrared Spectroscopy. Food Science, 2024, 45(2): 299-307. https://doi.org/10.7506/spkx1002-6630-20230418-177

487

Views

0

Downloads

0

Crossref

5

Scopus

4

CSCD

Received: 18 April 2023
Published: 25 January 2024
© Beijing Academy of Food Sciences 2024.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).