AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home Food Science Article
PDF (5.2 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Rapid Determination of Nine Acrylates in Food Contact Materials by Ultra Performance Convergence Chromatography

Yue QIU ( ), Chaolan TAN, Xiaoyu LIU, Jiali LU, Qiuling YU
Chongqing Academy of Metrology and Quality Inspection, Chongqing 401123, China
Show Author Information

Abstract

Ultra performance convergence chromatography (UPC2) was used to establish a rapid analytical method to determine nine acrylate compounds in plastic food contact materials simultaneously. The samples were extracted with methanol, filtered through an organic membrane, and separated on an ACQUITY UPC2 HSS C18 SB column with gradient elution using a mobile phase consisting of supercritical carbon dioxide and acetonitrile. The photodiode array (PDA) detector was set at 210 nm. Experimental results showed that under the optimal conditions (column temperature, 40 ℃; and back pressure, 13.79 MPa), qualitative and quantitative analysis of the nine acrylates was completed within 4 min. Linear ranges were 0.2–100 mg/L for phenyl methacrylate (PNMA), benzyl methacrylate (BZMA) and ethylene dimethacrylate (EDMA); 0.3–100 mg/L for methacrylic acid (MAA); 0.4–100 mg/L for butyl acrylate (BTA), hydroxyethyl methylacrylate (HEMA) and hydroxyethyl acrylate (HEA); and 0.5–100 mg/L for isobutylmeth acrylate (IBMA) and benzyl acrylate (BZA). The determination coefficients (R2) of the standard curves for all acrylates were higher than 0.9985, and recoveries obtained at high (30 mg/kg), middle (6 mg/kg) and low (0.2, 0.3, 0.4 and 0.5 mg/kg) spiked concentrations ranged from 89.3% to 109.7%, with relative standard deviations of 0.62% to 3.86% (n = 6). The limits of detection (RSN ≥ 3) were 0.05–0.15 mg/kg, and the limits of quantification (RSN ≥ 10) were 0.2–0.5 mg/kg. The proposed method identified the risk of acrylate residues in 30 batches of actual samples.

CLC number: O657.99 Document code: A Article ID: 1002-6630(2024)01-0225-07

References

【1】
【1】
 
 
Food Science
Pages 225-231

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
QIU Y, TAN C, LIU X, et al. Rapid Determination of Nine Acrylates in Food Contact Materials by Ultra Performance Convergence Chromatography. Food Science, 2024, 45(1): 225-231. https://doi.org/10.7506/spkx1002-6630-20230328-276

496

Views

1

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 28 March 2023
Published: 15 January 2024
© Beijing Academy of Food Sciences 2024.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).