AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home Food Science Article
PDF (5.8 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Application and Mechanism of High-Sensitivity Indicator Film for Monitoring Fish Freshness

Tong SHI Huiling HUZhiyu XIONGLin WANGLi YUANRuichang GAO ( )
School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China
Show Author Information

Abstract

The sensitivity of freshness indicator labels/films has become an important research direction of intelligent food packaging. In this study, a high-sensitivity indicator film containing gelatin and Fe2+ was prepared by electrospinning using blueberry anthocyanins as the indicator and zein as the matrix for monitoring fish freshness. The validity and sensitivity of the indicator film for detecting the freshness of silver carp were tested and the potential mechanism was elucidated. The results of pH sensitivity, ammonia sensitivity and anthocyanin release showed that the addition of gelatin and Fe2+ improved the sensitivity of the indicator film to pH and ammonia, and contributed to better binding of the anthocyanins in the film. There was a strong correlation between the color response (P = (L* + a* + b* + R + G + B)/a*) of the film and the content of total volatile basic nitrogen (TVB-N) content in fish meat as a freshness indicator (R2 > 0.98). In conclusion, the prepared indicator film can effectively monitor fish freshness, and the hydrogen bond interactions between anthocyanins and gelatin/Fe2+ may affect the color response characteristics and sensitivity of the indicator film.

CLC number: TS254.4 Document code: A Article ID: 1002-6630(2023)13-0150-09

References

【1】
【1】
 
 
Food Science
Pages 150-158

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
SHI T, HU H, XIONG Z, et al. Application and Mechanism of High-Sensitivity Indicator Film for Monitoring Fish Freshness. Food Science, 2023, 44(13): 150-158. https://doi.org/10.7506/spkx1002-6630-20220803-033

505

Views

0

Downloads

0

Crossref

3

Scopus

2

CSCD

Received: 03 August 2022
Published: 15 July 2023
© Beijing Academy of Food Sciences 2023.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).