AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home Food Science Article
PDF (2.9 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Determination of Pentachlorophenol in Milk Powder by Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry

Yan QI , Jinqing LI ( ), Cong LI, Qingpeng XU
Guangdong Testing Institute of Product Quality Supervision, Shunde 528300, China
Show Author Information

Abstract

In this study, an analytical method was established to determine pentachlorophenol (PCP) in milk powder by isotope dilution-liquid chromatography-tandem mass spectrometry (LC-MS/MS). The sample was dissolved in water, extracted by the quick, effective, cheap, easy, rugged and safe (QuEChERS) method using acetonitrile as the extraction solvent and protein precipitant, purified on a Captiva EMR-Lipid column, and diluted with the same volume of water before analysis. The chromatographic separation was achieved on a C18 column (100 mm × 2.1 mm, 1.7 μm) with gradient elution using a mobile phase composed of methanol and 5 mmol/L ammonium acetate solution (containing 0.05% formic acid), and then the analyte was detected with negative electrospray ionization (ESI-) in the multiple reaction monitoring (MRM) mode. Matrix matching-isotope dilution internal standard method was used for identification and quantification of the analyte. The results indicated that the calibration curve of PCP was linear in the concentration range of 0.2‒150 μg/L with correlation coefficients (r) not less than 0.9960. The limits of detection (LOD) and quantitation (LOQ) of the method were 0.5 and 1.5 μg/kg, respectively. The average recoveries for spiked milk powder ranged from 90.3% to 119.2%, with relative standard deviation (RSD, n = 6) equal to or less than 7.5%. The method has the advantages of simple pretreatment without concentration or dissolution, high sensitivity, accuracy and reliability, and can be used as an effective method for detecting pentachlorophenol in milk powder.

CLC number: O657.6 Document code: A Article ID: 1002-6630(2023)16-0324-07

References

【1】
【1】
 
 
Food Science
Pages 324-330

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
QI Y, LI J, LI C, et al. Determination of Pentachlorophenol in Milk Powder by Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry. Food Science, 2023, 44(16): 324-330. https://doi.org/10.7506/spkx1002-6630-20220616-168

433

Views

0

Downloads

0

Crossref

1

Scopus

0

CSCD

Received: 16 June 2022
Published: 25 August 2023
© Beijing Academy of Food Sciences 2023.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).