AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home Food Science Article
PDF (3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Rapid Detection of Ametryn and Atrazine by a Novel Molecularly Imprinted Polymer-modified Selective Ion Source Coupled to Electrospray Ionization Mass Spectrometry

Hongyue MA1,2 Minli YANG2Feng ZHANG2 ( )Bingcheng YANG1Feifang ZHANG1 ( )
Pharmaceutical Engineering and Process of Chemical Engineering Research Center of Ministry of Education, School of Pharmacy, East China University of Science and Technology, Shanghai 200237, China
Key Laboratory of Food Quality and Safety for State Market Regulation, Chinese Academy of Inspection & Quarantine, Beijing 100176, China
Show Author Information

Abstract

A rapid method for the trace level detection of ametryn and atrazine residues in food matrices was developed by using a selective ambient mass spectrometry (AMS) ion source based on molecularly imprinted polymer modified iron sheet (MIPIS) in combination with electrospray ionization mass spectrometry (ESI-MS). Molecularly imprinted polymer (MIP) using cyanazine as template molecule was prepared by polymerization of methacrylic acid (MAA) and aniline in aqueous solution. MIPIS was used as an extraction tip for rapid enrichment of ametryn and atrazine in soy milk powder, wheat and milk before direct analysis by AMS ion source coupled to ESI-MS. The results showed that the linearity of this method ranged from 0.2 to 200 μg/L, with correlation coefficients of 0.9982 and 0.9997 for ametryn and atrazine, respectively. The average recoveries of ametryn and atrazine at three spiked levels ranged from 81.05% to 109.66%. The limits of detection (LODs) and the limits of quantification (LOQs) of the analytes were 0.2–0.5 μg/kg and 0.6–1.5 μg/kg, respectively. This study has provided a simple and sensitive method that can effectively avoid the tedious sample pretreatment and timeconsuming chromatographic separation for rapid detection of trace levels of triazine pesticide residues in foods.

CLC number: TS201.6 Document code: A Article ID: 1002-6630(2022)16-0317-07

References

【1】
【1】
 
 
Food Science
Pages 317-323

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
MA H, YANG M, ZHANG F, et al. Rapid Detection of Ametryn and Atrazine by a Novel Molecularly Imprinted Polymer-modified Selective Ion Source Coupled to Electrospray Ionization Mass Spectrometry. Food Science, 2022, 43(16): 317-323. https://doi.org/10.7506/spkx1002-6630-20220223-182

385

Views

1

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 23 February 2022
Published: 25 August 2022
© Beijing Academy of Food Sciences 2022.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).