AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home Food Science Article
PDF (4.3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Construction of an Electrochemical Sensor Based on Mixed Aerogels Loaded with Silver Nanoparticles for the Determination of Hydrogen Peroxide in Foods

Cuizhong ZHANG , Zhenfa ZHANG, Gang XIANG, Qing HUANG, Huan LIAN, Fengping LIU, Wei HUANG, Shunian ZHOU, Xuming LI, Fuyan LI ( )
Photochemical Sensing and Regional Environmental Analysis Laboratory, Chemical and Biological Engineering College, Guangxi Normal University for Nationalities, Chongzuo 532200, China
Show Author Information

Abstract

Carboxy carbon nanotubes and dialyzed graphene oxide were bound via amio and carboxyl groups using polydopamine as a cross-linking agent to form a three-dimensional mixed aerogel (MA) with a hierarchical porous structure. Silver nanoparticles were loaded in situ onto MA to develop an efficient electrochemical method for the detection of hydrogen peroxide in foods. The response current to hydrogen peroxide of AgNPs-MA modified electrode was 24.5 times higher than that of bare glassy carbon electrode under the optimal conditions (pH 7.4, working bias of -0.4 V and 5 μL of modified electrode solution). Chronoamperometry was used to detect hydrogen peroxide rapidly and sensitively. The peak current of the modified electrode had a good linear relationship with the concentration of hydrogen peroxide, which was fitted the following equation: I = 0.32c + 1.66 (R2 = 0.9993), and the limit of detection (LOD) was 0.02 μmol/L (signal-to-noise ratio, RSN = 3). In addition, the electrochemical sensor had high accuracy, stability and anti-interference performance, and could be reused. The sensor was applied to the monitoring of hydrogen peroxide in milk, with a recovery rate of 98.1%–98.8% and a relative standard deviation (RSD) of 0.58%–2.28%. It is expected to be applied to the rapid trace detection of hydrogen peroxide in foods.

CLC number: TS207.3 Document code: A Article ID: 1002-6630(2022)18-0332-07

References

【1】
【1】
 
 
Food Science
Pages 332-338

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHANG C, ZHANG Z, XIANG G, et al. Construction of an Electrochemical Sensor Based on Mixed Aerogels Loaded with Silver Nanoparticles for the Determination of Hydrogen Peroxide in Foods. Food Science, 2022, 43(18): 332-338. https://doi.org/10.7506/spkx1002-6630-20211122-269

475

Views

3

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 22 November 2021
Published: 25 September 2022
© Beijing Academy of Food Sciences 2022.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).