AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home Food Science Article
PDF (4.2 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Enzyme-free Electrochemical Sensor for Glucose Detection Based on Nickel-based Basic Carbonate Modified Electrode

Li LIU1 Zhifeng ZHANG2Songlei WANG1 ( )Haifeng LI1Kenken LI1Liang MA1Peiyuan WEI1Ye ZHANG1Kangning WU3
School of Food and Wine, Ningxia University, Yinchuan 750021, China
School of Food Science and Technology, Huazhong Agricultural University, Wuhan 430000, China
Huaxinda Health Technology Company of Ningxia, Lingwu 751400, China
Show Author Information

Abstract

Based on transition metal nickel-based basic carbonate (Ni-CHs) grown in situ on carbon paper (Ni-CHs/CP), prepared by one-step hydrothermal method, a highly sensitive and selective enzyme-free sensor to detect glucose was developed. X-ray diffraction (XRD) and scanning electron microscopy (SEM) were used to identify the phase and characterize the morphology of the material. Cyclic voltammetry (CV) and time-current curve were used to evaluate the performance of the sensor. The results showed that Ni-CHs/CP had the best detection ability for glucose at a low potential of 0.5 V, and the oxidation peak current of the sensor showed an excellent linear relationship with glucose concentration in the range of 0.95 μmol/L–2.623 mmol/L, with a correlation coefficient of 0.998. The detection limit was 0.31 μmol/L (RSN = 3) and response time was 3.5 s. This sensor has good stability and has been successfully used in the detection of actual samples with spiked recoveries of 95.65%–105.56%.

CLC number: TS251.7 Document code: A Article ID: 1002-6630(2022)08-0339-07

References

【1】
【1】
 
 
Food Science
Pages 339-345

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
LIU L, ZHANG Z, WANG S, et al. Enzyme-free Electrochemical Sensor for Glucose Detection Based on Nickel-based Basic Carbonate Modified Electrode. Food Science, 2022, 43(8): 339-345. https://doi.org/10.7506/spkx1002-6630-20210510-107

303

Views

1

Downloads

0

Crossref

2

Scopus

0

CSCD

Received: 10 May 2021
Published: 25 April 2022
© Beijing Academy of Food Sciences 2022.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).