AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home Food Science Article
PDF (4.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Multi-objective Rapid Screening of 30 Protein Assimilation Hormones and Glucocorticoids in Fish by Ultra-high Performance Liquid Chromatography Coupled to Quadrupole/Orbitrap High-Resolution Mass Spectrometry

Tianrong GUO1 , Wenlin WU1,2,3 ( ), Yin ZHANG4 ( ), Yuping WAN1, Mei YE1, Daiwei CHEN1, Xia HUANG2,3, Longyi ZHANG4
Chengdu Institute of Food Inspection, Chengdu 611130, China
Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu 610041, China
University of Chinese Academy of Sciences, Beijing 100049, China
Key Laboratory of Meat Processing of Sichuan, Chengdu University, Chengdu 610106, China
Show Author Information

Abstract

A method for rapid screening and identification of 30 protein assimilation hormones and glucocorticoids in fish was established using ultra-high performance liquid chromatography coupled to quadrupole/orbitrap high-resolution mass spectrometry (UPLC-Q/Orbitrap HRMS). The samples were extracted with 80% acetonitrile aqueous solution (containing 0.2% formic acid), centrifuged, purified by solid phase extraction (SPE) on Oasis PRiME HLB column, and dried with nitrogen blow. The residue was re-dissolved. The chromatographic separation was performed on a Waters Acquity BEH C18 (2.1 mm × 100 mm, 1.7 μm) column through gradient elution using a mobile phase consisting of 20 mmol/L ammonium acetate aqueous solution containing 0.1% formic acid (A) and acetonitrile (B). The target analytes were detected in the positive and negative ion mode using a heated electrospray ionization (HESI) source through primary full scan/data-dependent secondary scan (full MS/dd-MS2) monitoring, and quantitated by matrix-matched external standard method. The results showed that good linearity was observed for the 30 hormones in the concentration range of 0.5–100 ng/mL with correlation coefficients (r) greater than 0.9950. The limits of detection were between 0.2 and 1.0 μg/kg, and the limits of quantification were between 0.5 and 2.0 μg/kg. The recoveries were 69.7%–103.2% with relative standard deviations (RSDs) of 2.3%–9.4% at three spiked levels for four different fishes (turbot, mandarin fish, mullet and grass carp). The proposed method is efficient, accurate and reliable, and is suitable for the rapid multi-objective screening and quantitative analysis of protein assimilation hormones and glucocorticoids in fish.

CLC number: TS207.3 Document code: A Article ID: 1002-6630(2022)04-0321-10

References

【1】
【1】
 
 
Food Science
Pages 321-330

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
GUO T, WU W, ZHANG Y, et al. Multi-objective Rapid Screening of 30 Protein Assimilation Hormones and Glucocorticoids in Fish by Ultra-high Performance Liquid Chromatography Coupled to Quadrupole/Orbitrap High-Resolution Mass Spectrometry. Food Science, 2022, 43(4): 321-330. https://doi.org/10.7506/spkx1002-6630-20210203-047

420

Views

3

Downloads

0

Crossref

4

Scopus

4

CSCD

Received: 03 February 2021
Published: 25 February 2022
© Beijing Academy of Food Sciences 2022.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).