Development and Application of Recombinase-Aided Amplification Combined with Lateral Flow Dipstick Assay for Rapid Detection of Staphylococcus aureus

Laiwang HOU1 , Darong LI1, Bo DENG2, Yong ZHAO1,3,4, Yingjie PAN1,3,4, Dongsheng FENG2, Xiaohong SUN1,3,4 ( )
College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China
Shanghai Agricultural Products Quality and Safety Testing Center, Shanghai 201799, China
Laboratory of Quality & Safety Risk Assessment for Aquatic Products on Storage and Preservation (Shanghai), Ministry of Agriculture and Rural Affairs, Shanghai 201306, China
Shanghai Engineering Research Center of Aquatic-product Processing & Preservation, Shanghai 201306, China
Show Author Information

Abstract

In this study, our aim was to establish a sensitive and rapid approach for the visual and point-of-care detection of Staphylococcus aureus using recombinase-aided amplification (RAA) and lateral flow dipstick (LFD). We designed and screened three pairs of specific primers targeting conserved sequences in the nuc gene of S. aureus and optimized reaction conditions. The RAA-LFD assay took 20 min to amplify the target gene with a 200 nmol/L primer concentration at 33 ℃. The specificity analysis exhibited no cross-reaction with other pathogens. The sensitivity of the RAA-LFD method was as low as 4 fg/μL for DNA and 1.83 × 102 CFU/mL for pure cultures. The reliability was verified using artificially contaminated milk samples, showing that the limit of detection (LOD) was 1.83 × 101 CFU/mL after 6 h enrichment. When 64 milk samples were tested for S. aureus using the traditional culture method, polymerase chain reaction (PCR) and the RAA-LFD method, the results of RAA-LFD showed a high total coincidence rate of 95.3% and 98.4% with those of the two former methods respectively. The visual detection method established in this study has the characteristics of high specificity, high sensitivity, rapidity, simple operation, and low requirements for equipment, and can provide a new development direction for the detection of S. aureus in milk.

CLC number: R155.5 Document code: A Article ID: 1002-6630(2022)04-0331-09

References

【1】
【1】
 
 
Food Science
Pages 331-339

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
HOU L, LI D, DENG B, et al. Development and Application of Recombinase-Aided Amplification Combined with Lateral Flow Dipstick Assay for Rapid Detection of Staphylococcus aureus . Food Science, 2022, 43(4): 331-339. https://doi.org/10.7506/spkx1002-6630-20201215-178

629

Views

2

Downloads

0

Crossref

5

Scopus

2

CSCD

Received: 15 December 2020
Published: 25 February 2022
© Beijing Academy of Food Sciences 2022.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).