AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home Food Science Article
PDF (2.5 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Determination of Vitamins A, D and E in Health Foods Using Column-Switching Liquid Chromatography

Liyuan ZHANG ( ), Lüye QI, Minghao ZHOU
Zhejiang Institute for Food and Drug Control, Hangzhou 310052, China
Show Author Information

Abstract

A method for the determination of vitamins A (VA), D (VD) and E (VE) in health foods by column-switching two-dimensional liquid chromatography was established. According to the sample pretreatment method specified in the national standard GB 5009.82-2016, VA and four isomers of VE were separated on an Agilent Poroshell 120 PFP column (4.6 mm × 100 mm, 2.7 μm) as one-dimensional chromatographic column using a mobile phase consisting of methanol and water by gradient elution, and VD2 and VD3 were separated on an Agilent Zorbax Eclipse PAH column (2.1 mm × 100 mm, 3.5 μm) by gradient elution using a mobile phase composed of methanol and acetonitrile. VD was captured on an Agilent Poroshell 120 EC C18 column (4.6 mm × 5 mm, 4 μm). According to the peak time of VD on the one-dimensional chromatographic column, the column switching time was determined. The one-dimensional detection wavelengths were 325 and 294 nm, and the two-dimensional detection wavelength was 264 nm. The analytes were quantified by external standard method. Results indicated that the calibration curves were linear in the range of 2.50-50.0 μg/mL for VA, and 0.10-2.00 μg/mL for VD, and 5.00-100.0 μg/mL for VE, and the correlation coefficients were all more than 0.999. The recoveries were 86%–102%, with relative standard deviations (RSD) of 1.5%–4.0%. The results suggest that the developed method is accurate and suitable for the determination of VA, VD and VE in health foods.

CLC number: TS207.3 Document code: A Article ID: 1002-6630(2022)04-0225-06

References

【1】
【1】
 
 
Food Science
Pages 225-230

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHANG L, QI L, ZHOU M. Determination of Vitamins A, D and E in Health Foods Using Column-Switching Liquid Chromatography. Food Science, 2022, 43(4): 225-230. https://doi.org/10.7506/spkx1002-6630-20201106-062

444

Views

3

Downloads

0

Crossref

4

Scopus

2

CSCD

Received: 06 November 2020
Published: 25 February 2022
© Beijing Academy of Food Sciences 2022.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).