AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Analysis & Detection | Publishing Language: Chinese | Open Access

Establishment and Optimization of Analytical Method for Detection of Volatile Flavor Compounds in Dry-Cured Fish

Fangxue CHEN1,2 Shizhe WANG1,2Wenxing QIU1,2Guangquan XIONG1Yu QIAO1 ( )Wenjin WU1Lan WANG1
Institute of Agricultural Products Processing and Nuclear Agriculture Technology, Hubei Academy of Agricultural Sciences, Wuhan 430064, China
School of Biological Engineering and Food, Hubei University of Technology, Wuhan 430068, China
Show Author Information

Abstract

A gas chromatography-mass spectrometric (GC-MS) method was developed for the detection of volatile flavor compounds in dry-cured blunt snout bream. Analytical conditions such as extraction temperature, solid-phase microextraction (SPME) probe, headspace vial, chromatographic column, and extraction techniquewere optimized based on the peak area of identified compounds (hexanal, heptanal, octanal, nonanal, 1-penten-3-ol, 1-pentanol, hexanol and 1-octen-3-ol). The results showed that a total of 85 volatile compounds were detected in dry-cured fish. More volatile compounds were extracted at 90 ℃ than at 40 ℃, indicating that more volatile compounds were produced by thermal reaction. Divinylbenzene-carboxen polydimethylsiloxane (DVB/CAR/PDMS) fiber could better adsorb volatile compounds from dry cured fish. Twenty-mL short headspace vials provided better adsorption efficiency for volatile compounds, but the adsorption efficiency was lower than that of tall headspace vials. The volatile compounds in dry-salted fish were separated better on a polar column with good reproducibility. More aldehydes and alcohols were detected using a DB-WAX column, more acids and esters were detected using an HP-INNOWAX column, and more hydrocarbons were separated using a DB-1 column with weak polarity. The results of headspace solid phase microextraction (HS-SPME), stir bar sorptive extraction (SBSE) or dynamic headspace extraction (DHS) combined with gas chromatography-mass spectrometry (GC-MS) showed that DHS extracted the most volatile compounds, SBSE extracted the least volatile compounds, and SPME provided the most efficient and rapid extraction of volatile flavor compounds. SPME and DHS were more suitable for the extraction of volatile compounds from dry-cured fish.

CLC number: TS254.4 Document code: A Article ID: 1001-8123(2023)08-0027-08

References

【1】
【1】
 
 
Meat Research
Pages 27-34

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
CHEN F, WANG S, QIU W, et al. Establishment and Optimization of Analytical Method for Detection of Volatile Flavor Compounds in Dry-Cured Fish. Meat Research, 2023, 37(8): 27-34. https://doi.org/10.7506/rlyj1001-8123-20230419-030

337

Views

2

Downloads

0

Crossref

Received: 19 April 2023
Published: 31 August 2023
© China Meat Research Center 2023.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).