AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.9 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Analysis & Detection | Publishing Language: Chinese | Open Access

Development of Ready-to-Use Quality Control Samples for Rapid Detection of Escherichia coli in Meat and Meat Products

Yalun ZHANG Chen CHENHui WANGTonghe ZHANGShuang ZHANGXian LIYongbo LI ( )
Hebei Engineering Research Center for Special Food Safety and Health, Key Laboratory of Special Food Supervision Technology for State Market Regulation, Hebei Food Safety Key Laboratory, Hebei Food Inspection and Research Institute, Shijiazhuang 050071, China
Show Author Information

Abstract

This paper developed a ready-to-use quality control sample which can be directly used without secondary culture for the rapid detection of Escherichia coli in meat and meat products by matrix assisted laser desorption/ionization time-offlight mass spectrometry (MALDI-TOF-MS). The sample was evaluated for homogeneity and stability. The results showed that the survival rate of the quality control sample prepared using the selected cryoprotectant was above 90%. The culture count result of the quality control sample (F = 0.567) was less than the critical value, suggesting good uniformity. The quality control sample was stable for 14 days at 37 and 25 ℃, and the resuscitation rates were 101.5% and 99.6% at −20 and 4 ℃ for 28 days, respectively. After 28 days of storage at 37 and −20 ℃, the results of MALDI-TOF-MS were consistent, indicating that the developed sample had good stability and met the requirements of quality control samples.

CLC number: TS201.3 Document code: A Article ID: 1001-8123(2023)03-0046-05

References

【1】
【1】
 
 
Meat Research
Pages 46-50

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHANG Y, CHEN C, WANG H, et al. Development of Ready-to-Use Quality Control Samples for Rapid Detection of Escherichia coli in Meat and Meat Products. Meat Research, 2023, 37(3): 46-50. https://doi.org/10.7506/rlyj1001-8123-20220919-127

364

Views

2

Downloads

0

Crossref

Received: 19 September 2022
Published: 31 March 2023
© China Meat Research Center 2023.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).