A compact dual - mode EMAT - ECT sensor with lift-off compensation for thickness gauging of coated aluminum plates

Xiuli Shi1, Qiangxin Li2, Qi Xiao3( )
Shanghai Baoshan Sparetime University, Baoshan Branch School of Shanghai Open University, Shanghai 200940, China
College of Information Science and Engineering, Northeastern University, Shenyang 110004, China
School of Mechanical and Power Engineerng, East China University of Science and Technology, Shanghai 200237, China
Show Author Information

Abstract

Electromagnetic acoustic transducers (EMATs) offer contactless, single-sided inspection for nuclear applications. In CAP1400 baffle plates, nonuniform protective coatings cause spatially varying lift-off distances that result in severe attenuation of signal amplitudes. Conventional EMAT systems cannot sense these lift-off variations, leading to unreliable thickness measurement results. To overcome this limitation, this paper presents a compact dual-mode EMAT-eddy current testing (ECT) sensor. Shear and longitudinal bulk waves are generated using a single M-shaped magnetizer and distributed excitation coils, enabling simultaneous generation and independent acquisition of both wave modes within a single scan. An integrated ECT channel estimates the local lift-off between the sensor and the specimen, and this information is used to compensate for the EMAT signal amplitude. Simulation results show a nonlinear decay of the bias magnetic field with lift-off. A quadratic polynomial is therefore utilized to fit this decay characteristic, and the resulting calibration curve is then used for compensation of the signal amplitude. The ECT channel is calibrated for lift-off estimation over 0−1 mm, with a maximum error of 0.038 mm. When this estimated lift-off is used to compensate for EMAT signals, the amplitude variation falls from 32% to 9%. Experimental validation was performed on a 10-mm-thick 5052-H32 aluminum plate. The longitudinal and shear waves returned thicknesses of 9.93 mm and 9.96 mm, respectively. These values are within 0.1 mm of the nominal thickness and are consistent with one another, offering cross-validation of the measurement. This work provides a practical solution for liftoff-tolerant thickness gauging of coated safety-critical structures in nuclear environments.

References

【1】
【1】
 
 
Journal of Measurement Science and Instrumentation
Pages 468-478

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Shi X, Li Q, Xiao Q. A compact dual - mode EMAT - ECT sensor with lift-off compensation for thickness gauging of coated aluminum plates. Journal of Measurement Science and Instrumentation, 2026, 17(3): 468-478. https://doi.org/10.62756/jmsi.1674-8042.2026040

6

Views

0

Downloads

0

Crossref

0

CSCD

Received: 08 June 2026
Revised: 29 July 2026
Accepted: 30 August 2026
Published: 01 September 2026
© The Author(s) 2026.

The articles published in this open access journal are distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits use, distribution and reproduction in any medium, provided the original work is properly cited.