AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.9 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Bionic tactile sensor based on starfish tube foot structure

Jiaqi WANG1,2Xiaopeng YANG1,2( )Yuxi WANG1,2Qiulin TAN1,2( )
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, China
Key Laboratory of Micro/Nano Devices and Systems, Ministry of Education, North University of China, Taiyuan 030051, China
Show Author Information

Abstract

Artificial tactile perception sensors have great application value in robotics, medical health, intelligent prosthetics, and human-computer interaction. However, existing sensors encounter difficulties in achieving high sensitivity, good linear response, and high spatial resolution, which has become a key problem restricting their practical application. Here, inspired by the tube foot system in starfish, we report the design, fabrication, and performance of a multi-level dome structure tactile sensor (MLDSTS) that provides simultaneous high sensitivity, excellent linearity, stability, and high resolution. Through a series of experiments, a comprehensive and systematic characterization and analysis of its sensing performance were conducted. The experimental results showed that the constructed multi-level dome array structure could effectively expand the linear detection range of the sensor while stably maintaining high spatial resolution. Its linear range was increased by about 2 times compared with the single-level dome structure, and realized segmented sensitive response. The sensor could detect weak external forces as low as 0.1 N, with a sensitivity of 1.309 V/N in the range of 0.1-3 N and 0.447 V/N in the range of 4-10 N, possessing both high precision and large-range detection capabilities. Through tests in various practical application scenarios such as respiration monitoring, water droplet detection, fabric texture recognition, and knuckle movement monitoring, it was confirmed that the sensor exhibited excellent stability and detection accuracy in different pressure scenarios, and its performance was significantly superior to that of single-dome structure sensors. The research results indicated that the multi-level dome structure provided an effective strategy to solve the industry problem that it was difficult to balance the sensitivity, linearity, and resolution of tactile sensors. With its comprehensively excellent performance, the MLDSTS sensor has broad application prospects in the fields of flexible electronics, intelligent health monitoring, human-computer interaction, and intelligent robots.

References

【1】
【1】
 
 
Journal of Measurement Science and Instrumentation
Pages 344-354

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
WANG J, YANG X, WANG Y, et al. Bionic tactile sensor based on starfish tube foot structure. Journal of Measurement Science and Instrumentation, 2026, 17(2): 344-354. https://doi.org/10.62756/jmsi.1674-8042.2026029

236

Views

4

Downloads

0

Crossref

0

CSCD

Received: 27 December 2025
Revised: 31 January 2026
Accepted: 01 March 2026
Published: 01 June 2026
© The Author(s) 2026.

The articles published in this open access journal are distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits use, distribution and reproduction in any medium, provided the original work is properly cited.