AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

High-precision microcavity pressure sensing aided by MLP and GRNN

Xiaohui WANG1,2Wei LI3( )Canjin WANG4Wenyao LIU3Jun TANG2 ( )
Department of Electronic Engineering, Taiyuan Institute of Technology, Taiyuan 030008, China
School of Semiconductors and Physics, North University of China, Taiyuan 030051, China
School of Instrument and Electronics, North University of China, Taiyuan 030051, China
State Key Laboratory of Media Convergence Production Technology and Systems, Xinhua Zhiyun Technology Co., Ltd., Hangzhou 310030, China
Show Author Information

Abstract

In response to the requirements for high-precision detection and diverse data scenarios in the field of intelligent optical sensing, this research combines whispering gallery mode (WGM) microcavity sensing with machine learning to solve the problems of low spectral information utilization, large random errors, and poor adaptability to data scales in the traditional microcavity sensing. Firstly, the WGM microcavity sensing system is used to collect transmission spectral datasets of different scales. Secondly, a multi-layer perceptron (MLP) deep learning algorithm based on full-spectrum feature mapping is adopted to train and test the datasets through hierarchical feature extraction and nonlinear fitting. The results show that the MLP achieves the test accuracy of 99.95% on large datasets. However, it exhibits poor performance on small datasets. Subsequently, the generalized regression neural network (GRNN) is introduced, leveraging its non-iterative training and strong local feature fitting advantages to optimize the small sample scenarios. The results indicate that the GRNN can achieve a test accuracy of 98.85% on small data sample datasets, improving by 10.29% compared to MLP. Finally, this study quantitatively compares and analyzes the test performance of MLP and GRNN models for five datasets of different scales, clarifying the performance advantages of the two models under different data conditions. This study fully utilizes the characteristics of MLP and GRNN models to achieve high-precision detection under different data scales, providing strong technical support for the application of intelligent optical microcavity sensing technology in various scenarios.

References

【1】
【1】
 
 
Journal of Measurement Science and Instrumentation
Pages 162-170

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
WANG X, LI W, WANG C, et al. High-precision microcavity pressure sensing aided by MLP and GRNN. Journal of Measurement Science and Instrumentation, 2026, 17(1): 162-170. https://doi.org/10.62756/jmsi.1674-8042.2026014

260

Views

14

Downloads

0

Crossref

0

CSCD

Received: 01 December 2025
Revised: 09 January 2026
Accepted: 12 January 2026
Published: 01 March 2026
© The Author(s) 2026.

The articles published in this open access journal are distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits use, distribution and reproduction in any medium, provided the original work is properly cited.