Motion intention recognition using surface electromyography and arrayed flexible thin-film pressure sensors

Lingyu BU1, Xiangguo YIN1,2, Mingxing LIN1( ), Jiahe LIU3
Key Laboratory of High-Efficiency and Clean Mechanical Manufacture of MOE, Nation Demonstration Center for Experimental Mechanical Engineering, School of Mechanical Engineering, Shandong University, Jinan 250061, China
School of Rehabilitation Science and Engineering, University of Health and Rehabilitation Sciences, Qingdao 266071, China
School of Rehabilitation Medicine, Shandong Second Medical University, Weifang 261053, China
Show Author Information

Abstract

Motion intention recognition is considered the key technology for enhancing the training effectiveness of upper limb rehabilitation robots for stroke patients, but traditional recognition systems are difficult to simultaneously balance real-time performance and reliability. To achieve real-time and accurate upper limb motion intention recognition, a multi-modal fusion method based on surface electromyography (sEMG) signals and arrayed flexible thin-film pressure (AFTFP) sensors was proposed. Through experimental tests on 10 healthy subjects (5 males and 5 females, age 23±2 years), sEMG signals and human-machine interaction force (HMIF) signals were collected during elbow flexion, extension, and shoulder internal and external rotation. The AFTFP signals based on dynamic calibration compensation and the sEMG signals were processed for feature extraction and fusion, and the recognition performance of single signals and fused signals was compared using a support vector machine (SVM). The experimental results showed that the sEMG signals consistently appeared 175±25 ms earlier than the HMIF signals (p<0.01, paired t-test). In offline conditions, the recognition accuracy of the fused signals exceeded 99.77% across different time windows. Under a 0.1 s time window, the real-time recognition accuracy of the fused signals was 14.1% higher than that of the single sEMG signal, and the system’s end-to-end delay was reduced to less than 100 ms. The AFTFP sensor is applied to motion intention recognition for the first time. And its low-cost, high-density array design provided an innovative solution for rehabilitation robots. The findings demonstrate that the AFTFP sensor adopted in this study effectively enhances intention recognition performance. The fusion of its output HMIF signals with sEMG signals combines the advantages of both modalities, enabling real-time and accurate motion intention recognition. This provides efficient command output for human-machine interaction in scenarios such as stroke rehabilitation.

References

【1】
【1】
 
 
Journal of Measurement Science and Instrumentation
Pages 486-497

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
BU L, YIN X, LIN M, et al. Motion intention recognition using surface electromyography and arrayed flexible thin-film pressure sensors. Journal of Measurement Science and Instrumentation, 2025, 16(4): 486-497. https://doi.org/10.62756/jmsi.1674-8042.2025047

1296

Views

76

Downloads

0

Crossref

0

CSCD

Received: 12 June 2025
Revised: 21 July 2025
Accepted: 25 September 2025
Published: 01 December 2025
© The Author(s) 2025.

The articles published in this open access journal are distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits use, distribution and reproduction in any medium, provided the original work is properly cited.