Human presence detection and heart rate estimation algorithm based on millimeter-wave radar

Xinxing ZHU1, Yixuan GAO1, Mingchao LI1, Enkang WU1, Xiaofeng GU1, Junge LIANG1,2( ), Tian YU1( ), Cong WANG3
School of Integrated Circuits, Jiangnan University, Wuxi 214122, China
RFIC Center, Kwangwoon University, Seoul 01897, Republic of Korea
School of Electronics and Information Engineering, Harbin Institute of Technology, Harbin 150001, China
Show Author Information

Abstract

Millimeter-wave radar, with advantages such as non-contact penetration detection and privacy protection, has become a promising solution for unobtrusive monitoring in the field of smart elderly care. To solve the problem of whether there are human body in the elderly care scene, this study proposed a method for judging the presence of a human body based on adaptive dual thresholds to reduce invalid vital sign detection in an empty environment. This method used a low-frequency energy ratio as the core judgment basis. It combined adaptive thresholds to accurately judge the presence of human targets, effectively reducing false detections caused by background interference. In addition, given the defect that variational mode extraction (VME) needs to rely on manual parameter adjustment based on empirical values, the crown porcupine optimization (CPO) algorithm is introduced to optimize the VME parameters adaptively, and the optimized VME is used to reconstruct the heartbeat signal to improve the signal purity. Then, the multiple signal classification (MUSIC) algorithm was used for spectrum analysis to improve the accuracy of heart rate estimation. The results show that in the experimental judgment of personnel, the miss rate in the case of personnel presence is 2.2%, and the false alarm rate in the case of no personnel is only 3.2%; the root mean square error and mean absolute error of the proposed heart rate (HR) estimation method are reduced by 4.4 beat per minute and 3.05 beat per minute respectively compared with the traditional VME, verifying its excellence.

References

【1】
【1】
 
 
Journal of Measurement Science and Instrumentation
Pages 473-485

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHU X, GAO Y, LI M, et al. Human presence detection and heart rate estimation algorithm based on millimeter-wave radar. Journal of Measurement Science and Instrumentation, 2025, 16(4): 473-485. https://doi.org/10.62756/jmsi.1674-8042.2025046

3579

Views

289

Downloads

0

Crossref

0

CSCD

Received: 30 May 2025
Revised: 02 July 2025
Accepted: 28 July 2025
Published: 01 December 2025
© The Author(s) 2025.

The articles published in this open access journal are distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits use, distribution and reproduction in any medium, provided the original work is properly cited.