A portable, low-cost lactate measurement system

Qingqing WANG1, Yu PAN1, Chuanxin YU1, Yanyan WANG1, Kaikai ZHANG1, Sheng LIU1,2( )
School of Computer Science and Technology, Huaibei Normal University, Huaibei 235000, China
Anhui Provincial Engineering Research Center of Cognitive Behavioral Intelligent Computing and Application, Huaibei 235000, China
Show Author Information

Abstract

Lactate, as a metabolite, plays a significant role in a number of fields, including medical diagnostics, exercise physiology and food science. Traditional methods for lactate measurement often involve expensive and cumbersome instrumentation. This study developed a portable and low-cost lactate measurement system, including independently detectable hardware circuits and user-friendly embedded software, computer, and smartphone applications. The experiment verified that the relative error of the detection current in the device circuit was less than 1%. The electrochemical performance was measured by comparing the [Fe(CN)6]3−/[Fe(CN)6]4− solution with the desktop electrochemical workstation CHI660E, and a nearly consistent chronoamperometry(CA) curve was obtained. Two modified lactate sensors were used for CA testing of lactate. Within the concentration range of 0.1 mmol·L−1 to 20 mmol·L−1, there was a good linear relationship between lactate concentration and steady-state current, with a correlation coefficient (R2) greater than 0.99 and good repeatability, demonstrating the reliability of the developed device. The lactate measurement system developed in this study not only provides excellent detection performance and reliability, but also achieves portability and low cost, providing a new solution for lactate measurement.

References

【1】
【1】
 
 
Journal of Measurement Science and Instrumentation
Pages 37-46

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
WANG Q, PAN Y, YU C, et al. A portable, low-cost lactate measurement system. Journal of Measurement Science and Instrumentation, 2025, 16(1): 37-46. https://doi.org/10.62756/jmsi.1674-8042.2025004

1003

Views

107

Downloads

0

Crossref

0

CSCD

Received: 08 August 2024
Revised: 18 December 2024
Accepted: 06 January 2025
Published: 01 March 2025
© The Author(s) 2025.

The articles published in this open access journal are distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits use, distribution and reproduction in any medium, provided the original work is properly cited.