AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3.9 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Non-PLL high-precision synchronous sampling method among lots of acoustics acquisition channels for underwater multilinear array seismic exploration system

Jiajia JIANG1( ), Jindong CUI1, Xianquan WANG1, Xiaodong LI2, Xianjun ZENG3, Dasen ZHOU3, Qingwang YAO1, Fajie DUAN1, Xiao FU1
State Key Lab of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
Beijing Dynamic GeoSolutions Co. Ltd., Beijing 100107, China
Guangzhou Marine Geological Survey, Guangzhou 510075, China
Show Author Information

Abstract

Synchronous sampling is very essential in underwater multilinear array seismic exploration system in which every acquisition node (AN) samples analog signals by its own analog-digital converter (ADC). Aiming at the problems of complex synchronous sampling method and long locking time after varying sampling rate in traditional underwater seismic exploration system, an improved synchronous sampling model based on the master-slave synchronous model and local clock asynchronous drive with non phase locked loop (PLL) is built, and a high-precision synchronous sampling method is proposed, which combines the short-term stability of local asynchronous driving clock with the master-slave synchronous calibration of local sampling clock. Based on the improved synchronous sampling model, the influence of clock stability, transmission delay and phase jitter on synchronous sampling error is analyzed, and a high-precision calibration method of synchronous sampling error based on step-by-step compensation of transmission delay is proposed. The model and method effectively realize the immunity of phase jitter on synchronous sampling error in principle, and compensate the influence of signal transmission delay on synchronous sampling error. At the same time, it greatly reduces the complexity of software and hardware implementation of synchronous sampling, and solves the problem of long locking time after changing the sampling rate in traditional methods. The experimental system of synchronous sampling for dual linear array is built, and the synchronous sampling accuracy is better than 5 ns.

References

【1】
【1】
 
 
Journal of Measurement Science and Instrumentation
Pages 41-50

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
JIANG J, CUI J, WANG X, et al. Non-PLL high-precision synchronous sampling method among lots of acoustics acquisition channels for underwater multilinear array seismic exploration system. Journal of Measurement Science and Instrumentation, 2022, 13(1): 41-50. https://doi.org/10.62756/jmsi.1674-8042.2022005

668

Views

61

Downloads

1

Crossref

0

CSCD

Received: 28 November 2021
Published: 01 March 2022
© The Author(s) 2022.

The articles published in this open access journal are distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits use, distribution and reproduction in any medium, provided the original work is properly cited.