AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (8.7 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Protocol | Open Access

Optimized tissue sample preparation for cryo-electron tomography using serial lift-out

Wenjing Du1,#Junhan Yang1,#Qiang Guo1,2( )
State Key Laboratory of Membrane Biology, Peking-Tsinghua Center for Life Sciences, Academy for Advanced Interdisciplinary Studies, School of Life Sciences, Peking University, Beijing 100871, China
Changping Laboratory, Beijing 102206, China

#Wenjing Du and Junhan Yang contributed equally to this work.

Show Author Information

Abstract

Cryo-electron tomography (cryo-ET) can provide invaluable insights into subcellular structures in their native environment at molecular resolution. Cryo-focused ion beam (cryo-FIB) has been widely adopted to obtain thin lamellae of cells suitable for tomographic data acquisition. However, its application to tissue samples faces significant limitations. The larger sample size extends milling time, reducing sample preparation throughput. Furthermore, the need for repeated, intricate lift-out procedures adds considerable time and complexity to the workflow. The serial lift-out technique, which can prepare multiple lamellae, increases throughput and better preserves the structural integrity of the tissue sample. Here we outline the workflow of the optimized serial lift-out method and provide a detailed protocol for its implementation, exemplified by a vitrified mouse liver tissue sample.

References

【1】
【1】
 
 
Biophysics Reports
Pages 216-224

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Du W, Yang J, Guo Q. Optimized tissue sample preparation for cryo-electron tomography using serial lift-out. Biophysics Reports, 2026, 12(4): 216-224. https://doi.org/10.52601/bpr.2025.250035

1

Views

0

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 26 June 2025
Accepted: 21 August 2025
Published: 31 August 2026
© The Author(s) 2026

This article is licensed under a Creative Commons Attribution 4.0 International (CC BY 4.0) License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.