AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Open Access

Evaluation of the Linear Dimensional Changes and Hardness of Gypsum Product / Stone Type Ⅳ after Adding Silica Nanoparticles

Ola Mohammed AljuboriAli Mohammad Ali Aljafery ( )Raja'a Mahdi Al-Mussawi
Department of Prosthodontics, College of Dentistry, University of Kufa, Najaf, Iraq
Show Author Information

Abstract

Dental gypsum is routinely used as an investing and molding material for prosthodontics restoration with some acceptable linear dimensional changes in the finished restorations. This study aimed to evaluate linear dimensional stability and surface hardness of dental stone type Ⅳ when adding silica nanoparticles to it. 40 type Ⅳ stone specimens were prepared from stainless steel molds for linear dimensional stability and plastic mold for hardness, 20 of which contained silica nanoparticles (test group) while the other 20 were without any addition (control group). Each group was divided into subgroups containing 10 specimens for each one in order to compare the dimensional stability and hardness of them. The linear dimensional changes were measured using a digital caliper, while the hardness was tested with Vickers' hardness test. The data were analyzed with t-test (two-sample assuming unequal variances) and p-value. The mean value of linear dimensional changes for the control group was -0.396 and -0.386 for specimens of the test group. Mean hardness was 50.638 for the control group and 53.295 for the test group. The difference was significant for linear dimensional changes and highly significant for hardness. Adding of silica nanoparticles improved the hardness and reduced the linear dimensional changes of type Ⅳ stone.

References

【1】
【1】
 
 
Nano Biomedicine and Engineering
Pages 227-231

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Aljubori OM, Aljafery AMA, Al-Mussawi RM. Evaluation of the Linear Dimensional Changes and Hardness of Gypsum Product / Stone Type Ⅳ after Adding Silica Nanoparticles. Nano Biomedicine and Engineering, 2020, 12(3): 227-231. https://doi.org/10.5101/nbe.v12i3.p227-231

1496

Views

171

Downloads

6

Crossref

6

Scopus

Received: 01 March 2020
Accepted: 03 July 2020
Published: 11 August 2020
© Ola Mohammed Aljubori, Ali Mohammad Ali Aljafery, and Raja›a Mahdi Al-Mussawi.

This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.