Fragility of open-topped oil storage tanks under wind in Patagonia

FAIN and FAE, National University of Comahue, 8300 Neuquén, Argentina
Institute of Advanced Studies in Engineering and Technology (IDIT), CONICET / National University of Cordoba, 5016 Córdoba, Argentina
Show Author Information

Abstract

Oil storage tank farms are complex systems and the eventual failure of one of their components could affect the whole system. A risk assessment requires identifying the magnitude of the damage that can occur under certain load levels. Fragility curves for oil storage tanks with a floating roof are obtained in this work, to estimate the probability of exceeding a given damage state under wind loads. Steel tanks with height-diameter ratio between 0.20 and 0.60 designed with American Petroleum Institute standard 650 are analyzed. The loads are represented by wind-speed and the structural response of the tank is evaluated through computational simulations using finite element analyses. Damage is characterized by deformations in the geometry of the cylinder and wind girder. Damage levels are obtained using linear bifurcation analysis and geometric nonlinear analysis with imperfections, and loads are related to wind speed based on wind data of Patagonia in Argentina. The fragility curves are constructed by means of a log-normal distribution. The results allow establishing ranges of wind speeds for which the damage can affect the integrity of the tank. It is expected that the present results serve as the basis for the development of simplified models, so that a much larger tank database may be considered.

References

【1】
【1】
 
 
Emergency Management Science and Technology
Article number: 19

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Jaca RC, Grill J, Pareti N, et al. Fragility of open-topped oil storage tanks under wind in Patagonia. Emergency Management Science and Technology, 2023, 3: 19. https://doi.org/10.48130/EMST-2023-0019

838

Views

9

Downloads

1

Crossref

1

Scopus

Received: 06 September 2023
Accepted: 13 November 2023
Published: 26 December 2023
© 2023 by the author(s).

This article is an open access article distributed under Creative Commons Attribution License (CC BY 4.0), visit https://creativecommons.org/licenses/by/4.0/.