Exergy Analysis of CO2 Centrifugal Reverse Brayton Cycle

Jiaole ZhouHao LiLi Wang( )
School of Civil Engineering and Architecture, Zhejiang Sci-Tech University, Hangzhou, 310018, China
Show Author Information

Abstract

The centrifugal reverse Brayton cycle (CRBC) is a novel refrigeration cycle that harnesses the conversion of inertial potential energy to pressure energy, enabling efficient compression and expansion processes through centrifugal and centripetal flows of the working fluid within a rotating tube. This offers a promising potential for improving the refrigeration efficiency of conventional gas refrigeration cycles. Building on previous studies, this study employs a thermodynamic model to conduct a parametric analysis of the CRBC to explore the thermodynamic efficiency and loss distributions of the cycle, providing a theoretical foundation for system evaluation and enhancement. Results show that, under the same inlet air temperature, an optimization possibility exists for the heater inlet temperature. The system experiences substantial exergetic losses during the centrifugal isothermal compression flow, adiabatic compression, and centripetal adiabatic expansion flow, each at approximately 20%. Conversely, the exergetic losses during the air-cooling process and the centrifugal adiabatic compression process are comparatively low and demonstrate an inverse relationship with the inlet temperature of the gas heater. The exergetic efficiency of the CRBC reaches 19.2%, which significantly surpasses the values of 8.1% for the CO2 reverse Brayton cycle, 4.9% for the open-air reverse Brayton cycle, and 2.3% for the closed-air reverse Brayton cycle.

CLC number: TB61+1;TB61+4 Document code: A Article ID: 0253-4339(2024)04-0093-11

References

【1】
【1】
 
 
Journal of Refrigeration
Pages 93-103

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zhou J, Li H, Wang L. Exergy Analysis of CO2 Centrifugal Reverse Brayton Cycle. Journal of Refrigeration, 2024, 45(4): 93-103. https://doi.org/10.3969/j.issn.0253-4339.2024.04.093

2

Views

0

Downloads

0

Crossref

0

CSCD

Received: 07 August 2023
Revised: 19 October 2023
Accepted: 02 November 2023
Published: 16 August 2024
© 2024 The Editorial Office of Journal of Refrigeration

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).