AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (6.9 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Charging Requirements and Unstable Characteristics of Automotive CO2 Thermal Management Systems

Congfei Wang1Fan Jia2,3Xiang Yin2Feng Cao2,3( )
Chinese Association of Refrigeration, Beijing, 100142, China
School of Energy and Power Engineering, Xi′an Jiaotong University, Xi′an, 710049, China
National Innovation Platform (Center) for Industry-Education Integration of Energy Storage Technology, Xi′an Jiaotong University, Xi′an, 710049, China
Show Author Information

Abstract

Transcritical CO2 thermal systems have emerged as leading solutions to addressing challenges such as "range anxiety in winter" and pronounced greenhouse effects associated with the working fluid in electric vehicle thermal systems. Nevertheless, the intricate interplay of transcritical cycles in the varied scenarios of electric vehicles introduces complexity, with performance and operational stability intricately linked to the refrigerant charge. This study conducts simulations to investigate the variability in refrigerant charging requirements for transcritical CO2 thermal management systems under diverse operating conditions. We specifically examined the impact of three critical factors, namely ambient temperature, indoor airflow rate, and outdoor air velocity, on refrigerant requirements in different modes and their underlying mechanisms. In the heat pump mode, the demand for refrigerant charge increases with ambient temperatures and wind speed and decreases with cabinet air flow rate, with changes of 18.6%, 18.9%, and 6.16%, respectively. In the cooling mode, the refrigerant charge requirement decreases with ambient temperatures and cabinet air flow rate and increases with outdoor wind speeds, with changes of 7.03%, 7.85%, and 2.27%, respectively. In situations of nonoptimal charging, potential alterations in the interaction between system control variables and target variables contribute to system instability. This necessitates adjustments to refrigerant distribution to mitigate instability under specific operating conditions. The research outcomes hold substantial reference value for the optimization of electric vehicle air-conditioning accumulator designs, enhancement of energy efficiency, and improvement of overall thermal comfort.

CLC number: TB61+2; U469.72 Document code: A Article ID: 0253-4339(2024)04-0059-09

References

【1】
【1】
 
 
Journal of Refrigeration
Pages 59-67

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Wang C, Jia F, Yin X, et al. Charging Requirements and Unstable Characteristics of Automotive CO2 Thermal Management Systems. Journal of Refrigeration, 2024, 45(4): 59-67. https://doi.org/10.3969/j.issn.0253-4339.2024.04.059

1

Views

0

Downloads

0

Crossref

0

CSCD

Received: 26 January 2024
Revised: 20 March 2024
Accepted: 21 March 2024
Published: 16 August 2024
© 2024 The Editorial Office of Journal of Refrigeration

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).