Performance Analysis of CO2 Heat Pump System Based on Ejector and Integrated Mechanical Subcooling

Baomin Dai1Peifang Yang1Shengchun Liu1( )Ruirui Zhao1Yu Cao1Lin Zhao1Chengzhan Li1Dongpeng Zhao1,2,3Peng Xiao4
Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, Tianjin, 300134, China
Post-Doctoral Research Center of China Automotive Engineering Research Institute Co.,Ltd., Chongqing, 401122, China
School of Mechanical Engineering, Tianjin University, Tianjin, 300350, China
Danhua Hongye Refrigeration Technology Co., Ltd., Tianjin, 300131, China
Show Author Information

Abstract

To reduce greenhouse gas emissions and improve the performance of space heating systems, a transcritical CO2 heat-pump heating system using an ejector and integrated mechanical subcooling (EJ-IMS) is proposed. A thermodynamic model of the system is developed with the coefficient of performance (COP) as the objective function, and the subcooling degree and discharge pressure are optimized. The winter heating performance of the system located in cities located in different climate zones was evaluated. The results show that the EJ-IMS system has a maximum COP, corresponding to the optimum subcooling degree and the optimum discharge pressure. The optimum subcooling degree is 26.44%-39.21% lower than that of the integrated mechanical subcooling system, and the optimum discharge pressure of the EJ-IMS system is 0.27%-9.37% lower than that of the baseline system and ejector system. The COP and exergetic efficiency of the EJ-IMS system are 6.09%-37.74% and 6.75%-46.02% higher than those of the three conventional systems, respectively. The heating seasonal performance factor of the EJ-IMS system is 6.89%-29.61% higher than those of the three systems, indicating that the EJ-IMS system is suitable in cold regions. This study provides a theoretical reference for the construction of efficient CO2 space-heating systems.

CLC number: TB61+1; TK11+4 Document code: A Article ID: 0253-4339(2024)04-0043-08

References

【1】
【1】
 
 
Journal of Refrigeration
Pages 43-50

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Dai B, Yang P, Liu S, et al. Performance Analysis of CO2 Heat Pump System Based on Ejector and Integrated Mechanical Subcooling. Journal of Refrigeration, 2024, 45(4): 43-50. https://doi.org/10.3969/j.issn.0253-4339.2024.04.043

1

Views

0

Downloads

0

Crossref

0

CSCD

Received: 30 March 2024
Revised: 09 May 2024
Accepted: 14 May 2024
Published: 16 August 2024
© 2024 The Editorial Office of Journal of Refrigeration

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).