Analysis of the Influence of Heat Transfer in the Nozzle Divergence Section of Transcritical CO2 Two-phase Ejector

Yibo FengYang HeJianqiang Deng( )
School of Chemical Engineering and Technology, Xi′an Jiaotong University, Xi′an, 710049, China
Show Author Information

Abstract

The motive flow state in a transcritical CO2 ejector significantly affects its performance. The heat transfer on the wall of the motive nozzle can change the motive flow state, and its effect on the performance of the ejector should be studied. A CFD model of the transcritical CO2 two-phase ejector is constructed based on the homogeneous equilibrium model. The influence of heat transfer in the nozzle divergence section on the performance and flow field structure of the transcritical CO2 two-phase ejector is simulated. The effect of heat transfer on the system performance of using a split ejector at the condenser outlet is analyzed. The results show that the entrainment ratio of the ejector increases with an increase in the heat flux at the nozzle divergence section and the length of the nozzle divergence section. The effect is not obvious and can be ignored under a moderate heat flux, i.e. less than 120 kW/m2 since the entrainment ratio changes within 1%. In addition, the heat transfer in the nozzle divergence section has a slight effect on the internal flow field of the ejector. The temperature of the internal flow in the nozzle divergence section increases slightly, the vapor quality at the ejector outlet rises slightly, and the Mach numbers of the mixed flow at the nozzle outlet and in the mixing chamber increase. In the condenser outlet split ejector expansion refrigeration system, the fluid is subcooled using the ejector, and the coefficient of performance (COP) of the system is significantly improved, with a maximum COP increase ratio of 8.89%. In general, heating the divergence section of the motive nozzle of the ejector exerts minimal effect on its performance. However, it significantly improves the performance of the condenser outlet split-ejector expansion refrigeration system.

CLC number: TB61+1;TB657.5 Document code: A Article ID: 0253-4339(2024)03-0072-09

References

【1】
【1】
 
 
Journal of Refrigeration
Pages 72-80

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Feng Y, He Y, Deng J. Analysis of the Influence of Heat Transfer in the Nozzle Divergence Section of Transcritical CO2 Two-phase Ejector. Journal of Refrigeration, 2024, 45(3): 72-80. https://doi.org/10.3969/j.issn.0253-4339.2024.03.072

1

Views

0

Downloads

0

Crossref

0

CSCD

Received: 31 March 2023
Revised: 08 June 2023
Accepted: 31 July 2023
Published: 16 June 2024
© 2024 The Editorial Office of Journal of Refrigeration

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).