Experimental Study on the Robustness and Off-design Performances of R32 Heat Pump System

Fujun Ju1Wenhuan Yang1Xiaolei Zhou1Xiaowei Fan1,2( )Yuanfei Fan1Lumei Yin1Zhenhua Zhu1
School of Energy and Environment, Zhongyuan University of Technology, Zhengzhou, 450007, China
School of Energy and Architectural Environment Engineering, Henan University of Urban Construction, Pingdingshan, 467036, China
Show Author Information

Abstract

The effects of an expansion valve opening on the robustness and system performance of an R32 heat pump system under variable heat source inlet temperatures and hot-water inlet temperatures are studied. The results show that the system has different superheat oscillation ranges under different operating conditions, and the heat source inlet temperature has a significant effect on the initial oscillation superheat, whereas the hot water inlet temperature has no obvious effect on it. Under the variable heat source inlet temperature (15-25 ℃) conditions, the heating capacities show different variation trends with the superheat, whereas the COP shows the same changing trends, and the maximum COP of the system is obtained within the superheat oscillation range. Under the variable hot water inlet temperature (30-40 ℃) conditions, the heating capacities and COP show the same trends with the superheat, and both of them reach the maximum values in the superheat oscillation range. Both the increase in the heat source inlet temperature and the decrease in the hot water inlet temperature can increase the maximum heating capacity and the maximum COP, which are 9.287 kW and 4.646, respectively when the heat source inlet temperature is 25 ℃, and 9.148 kW and 5.665, respectively, when the hot water inlet temperature is 30 ℃.

CLC number: TB657.5; TK124 Document code: A Article ID: 0253-4339(2024)02-0074-07

References

【1】
【1】
 
 
Journal of Refrigeration
Pages 74-80

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Ju F, Yang W, Zhou X, et al. Experimental Study on the Robustness and Off-design Performances of R32 Heat Pump System. Journal of Refrigeration, 2024, 45(2): 74-80. https://doi.org/10.3969/j.issn.0253-4339.2024.02.074

2

Views

0

Downloads

0

Crossref

0

CSCD

Received: 11 February 2023
Revised: 23 June 2023
Accepted: 29 June 2023
Published: 16 April 2024
© 2024 The Editorial Office of Journal of Refrigeration

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).