AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home BLASTING Article
PDF (7.9 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Hazard Effects and Mechanism of Thermo-electrical Synergistic Aging in Mining Polyethylene-insulated Conductors

Ying ZHANG1, Tao WANG1, Wen-wei WANG2, Fu-chao TIAN3, Lei XU4, Yi-fan LIN1, Kai-xuan TANG1( )
School of Safety Science and Emergency Management, Wuhan University of Technology, Wuhan 430070, China
Institute of Advanced Technology, University of Science and Technology of China, Hefei 230000, China
State Key Laboratory of Coal Mine Disaster Prevention and Control, China Coal Technology and Engineering Group Shenyang Research Institute, Shenfu Demonstration Zone 113122, China
Key Laboratory of Fire Prevention Technology, Shenyang Fire Science and Technology Research Institute of MEM, Shengyang 110034, China
Show Author Information

Abstract

Electrical fires caused by cable degradation constitute a critical ignition source for gas and dust explosions in underground mining environments, where aged cable insulation serves as the primary contributing factor. Under harsh mining conditions, characterized by elevated ambient temperatures and high operating voltages, electrical cables experience accelerated electrothermal aging due to synergistic temperature-voltage degradation mechanisms. However, existing studies have primarily concentrated on investigating the influence of individual stress factors on cable fire behavior. To address this research gap, this study developed an electro-thermal synergistic aging platform and conducted comparative investigations of flame propagation characteristics and thermal stability for two different-sized polyethylene(PE) wires using flame spread tests and simultaneous thermal analysis(TG-DSC), under both electro-thermal synergistic aging and pure thermal aging conditions. The results demonstrate that electro-thermal synergistic aging, compared to thermal aging alone, reduces the flame spread rate and mass loss rate to 91% and 71%, respectively, while significantly increasing molten dripping frequency. Furthermore, the insulation layer exhibits an earlier melting peak, a delayed decomposition peak, and more substantial increases in residual carbon content. These findings elucidate the synergistic effects of electrical and thermal stresses on the combustion and pyrolysis behavior of PE wire, offering valuable theoretical insights for fire risk assessment and prevention in underground mining electrical systems.

CLC number: TM247 Document code: A Article ID: 1001-487X(2025)04-0215-08

References

【1】
【1】
 
 
BLASTING
Pages 215-222

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHANG Y, WANG T, WANG W-w, et al. Hazard Effects and Mechanism of Thermo-electrical Synergistic Aging in Mining Polyethylene-insulated Conductors. BLASTING, 2025, 42(4): 215-222. https://doi.org/10.3963/j.issn.1001-487X.2025.04.023

677

Views

2

Downloads

0

Crossref

0

Scopus

Received: 16 April 2025
Published: 19 May 2025
© 2025 Blasting Magazine Editorial Office

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).