Research Article | Open Access

Multifractal time series analysis of grounding resistance in transmission line towers under cold-climate conditions

Guangxin Zhang1Minzhen Wang1Jian Wang2Junseok Kim3( )
College of Science and Technology, Ningbo University, Ningbo, 315300, China
School of Mathematics and Statistics, Nanjing University of Information Science and Technology, Nanjing, 210044, China
Department of Mathematics, Korea University, Seoul, 02841, Republic of Korea
Show Author Information

Abstract

In this paper, we investigated the influence of climatic factors, particularly low temperature and humidity, on the grounding resistance of transmission towers in severely cold regions. Drawing on a full year of field monitoring data, we first identified a clear negative linear correlation between temperature and grounding resistance. Notably, the inclusion of precipitation as an additional variable led to a significant increase in the model's explanatory power and indicated that the resistance behavior was influenced by multiple environmental factors. To further explore the nonlinear and dynamic aspects of this relationship, we used multifractal detrended fluctuation analysis (MF-DFA) and multifractal detrended cross-correlation analysis (MF-DCCA). The computational results showed that the resistance time series exhibits strong multifractal characteristics and suggests high variability across temporal scales. Moreover, the combined influence of temperature and precipitation demonstrated a markedly stronger cross-correlation with resistance than temperature alone. These findings emphasize the complex and multiscale nature of grounding behavior in harsh climates and underscore the importance of moving beyond simplified linear models. Our research offers both methodological insights and practical implications for the design, maintenance, and risk assessment of power transmission infrastructure operating under extreme weather conditions, particularly in high-latitude or alpine environments.

CLC number: 37M10, 62M10

References

【1】
【1】
 
 
AIMS Mathematics
Pages 27985-28003

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zhang G, Wang M, Wang J, et al. Multifractal time series analysis of grounding resistance in transmission line towers under cold-climate conditions. AIMS Mathematics, 2025, 10(11): 27985-28003. https://doi.org/10.3934/math.20251229

116

Views

2

Downloads

0

Crossref

0

Web of Science

0

Scopus

Received: 22 July 2025
Revised: 18 November 2025
Accepted: 26 November 2025
Published: 28 November 2025
©2025 the Author(s), licensee AIMS Press.

This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0)