Research Article | Open Access

Experimental investigation on cooling tower performance with Al2O3, ZnO and Ti2O3 based nanofluids

Habibur Rahman1Altab Hossain2( )Mohammad Ali3
Department of Mechanical Engineering, Military Institute of Science and Technology (MIST), Dhaka-1216, Bangladesh
Department of Mechanical Engineering, Engineering Faculty (MIST), BMA, Chattogram-4315, Bangladesh
Department of Mechanical Engineering, Bangladesh University of Engineering and Technology (BUET), Dhaka-1000, Bangladesh
Show Author Information

Abstract

This study deals with an experimental investigation of the thermal performance of a prototype mechanical wet cooling tower with a counter flow arrangement. Different volume concentrations ranging from 0.18 to 0.50 vol.% of stable Al oxide (Al2O3), Zn oxide (ZnO), and Ti oxide (Ti2O3) nanoparticles of 80, 35, and 70 nm diameter were considered. Water was taken as a base fluid, and the experiment was carried out at 60, 70, and 80 ℃, respectively, in laboratory conditions. The study revealed that an increase in the volume concentration of the nanofluids increased the cooling range, cooling efficiency, convective heat transfer coefficient, tower characteristic called number of transfer unit (NTU), and effectiveness of the cooling tower compared with water at the same mass flow rate and inlet temperature. However, increasing the volume concentration increased the viscosity of the nanofluids, leading to an increase in friction factor. For instance, for 0.18% volume concentration of ZnO, at an inlet water temperature of 66.4 ℃ and water/air (L/G) flow ratio of 1.93, the cooling range increased by 3.62%, cooling efficiency increased by 33.3%, and NTU increased by 50.5% compared with fresh water (FW).

References

【1】
【1】
 
 
AIMS Materials Science
Pages 935-949

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Rahman H, Hossain A, Ali M. Experimental investigation on cooling tower performance with Al2O3, ZnO and Ti2O3 based nanofluids. AIMS Materials Science, 2024, 11(5): 935-949. https://doi.org/10.3934/matersci.2024045

109

Views

2

Downloads

0

Crossref

0

Web of Science

0

Scopus

Received: 24 July 2024
Revised: 17 August 2024
Accepted: 27 August 2024
Published: 15 October 2024
©2024 the Author(s), licensee AIMS Press.

This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0)