AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Open Access

The load-bearing of composite slabs with steel deck under natural fires

Marcílio M. A. Filho1Paulo A. G. Piloto2( )Carlos Balsa3
ISISE, Department of Civil Engineering, Universidade do Minho, Campus Azurém, 4800-058, Portugal
LAETA INEGI, Instituto Politécnico de Bragança, Campus Santa Apolónia, 5300-253, Portugal
Research Centre in Digitalization and Intelligent Robotics (CeDRI), Instituto Politécnico de Bragança, Campus Santa Apolónia, 5300-253, Portugal
Show Author Information

Abstract

Composite slabs with steel deck combine the load-bearing resistance of the steel deck and rebar with the compressive resistance of the concrete (components). Unprotected composite slabs may be exposed to natural fire conditions from below, and steel reduces its load-bearing capacity during the heating stage. In short fire events, with limited deformations, the composite slabs can recover the load-bearing capacity during the cooling stage. This research presents the validation of the numerical model and the development of a parametric study, to evaluate the load-bearing capacity during the fire event. This method includes a time step procedure, based on the average temperature calculation for each component, including the reduction coefficients applied to the design strength of each material. A new proposal is also presented to evaluate the residual load-bearing capacity. In some circumstances, the residual load-bearing can be reduced by more than 20%. The results showed that the highest variation in the load-bearing resistance of composite slabs occurs when the steel temperatures are between 20 and 600 ℃, after this temperature, the steel has already lost most of its mechanical strength. Moreover, it was observed that different heating rates and different cooling rates influence the rate of the reduction and recovery of the load-bearing capacity. It was also noticed that the lowest load-bearing capacity of the composite slabs was reached after the end of the heating phase, showing that the stability of the element during the heating phase does not guarantee fire safety during the cooling phase.

References

【1】
【1】
 
 
AIMS Materials Science
Pages 150-171

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Filho MMA, Piloto PAG, Balsa C. The load-bearing of composite slabs with steel deck under natural fires. AIMS Materials Science, 2022, 9(1): 150-171. https://doi.org/10.3934/matersci.2022010

10

Views

0

Downloads

6

Crossref

4

Web of Science

8

Scopus

Received: 24 November 2021
Revised: 28 December 2021
Accepted: 09 January 2022
Published: 15 February 2022
©2022 the Author(s), licensee AIMS Press.

This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0)