AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.5 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Open Access

On the effect of using different penetrometers on CPTU test results on AMU-Morasko test site

Jędrzej Wierzbicki1( )Katarzyna Stefaniak1Waldemar Wołyński2Łukasz Smaga2Dawid Matusiak3
Institute of Geology, Adam Mickiewicz University Poznań, Poland
Faculty of Mathematics and Computer Science, Adam Mickiewicz University Poznań, Poland
Grunt-Test, Poznań, Poland
Show Author Information

Abstract

Investigations were conducted at the test site of Adam Mickiewicz University in Poznań. The test site is located in the northern part of Poznań, within the marginal zone of the Poznań Phase of the Weichselian (Vistulian) glaciation. The subsoil consists of glacial till from the Vistulian glaciation, separated by fluvioglacial sandy sediments, and is covered with fine and medium sands with single grains of gravel. The quality of the geotechnical parameters of the tested subsoil was assessed for the constrained modulus and undrained shear strength. To determine these parameters, static penetrometers from two different manufacturers were used. The tests and the result analysis were performed in three stages. In the first stage, each penetrometer was used to investigate the homogeneity and diversification of the subsoil structure in the test sites. The subsoil structure diversification was examined by grouping statistically similar Rf coefficient values along the profile. In the second stage, the level of accuracy and precision in the assessment of the corrected cone resistance (qt), friction on the friction sleeve (fs), and pore pressure (u2) were determined for individual penetrometers. In the final stage, differences between the constrained modulus and undrained shear strength were determined for both penetrometers. This analysis took into account the level of precision of the corrected cone resistance.

References

【1】
【1】
 
 
AIMS Geosciences
Pages 1007-1022

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Wierzbicki J, Stefaniak K, Wołyński W, et al. On the effect of using different penetrometers on CPTU test results on AMU-Morasko test site. AIMS Geosciences, 2025, 11(4): 1007-1022. https://doi.org/10.3934/geosci.2025044

4

Views

0

Downloads

0

Crossref

0

Web of Science

Received: 29 April 2025
Revised: 01 September 2025
Accepted: 09 October 2025
Published: 15 December 2025
©2025 the Author(s), licensee AIMS Press.

This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0)