AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.7 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Open Access

Robust multi-person vital-sign sensing in indoor environments using FMCW MIMO radar

Dongsheng Lai1Zhiming Cai1,2( )Ganhong Tian1Jiangchao Zhang1Long Chen1
School of Electronic, Electrical Engineering and Physics in Fujian University of Technology, Fuzhou 350000, China
National Demonstration Center for Experimental Electronic Information and Electrical Technology Education, Fujian University of Technology, Fuzhou 350000, China
Show Author Information

Abstract

Contactless monitoring of respiration and heart rate in shared indoor spaces—such as hospital wards, eldercare facilities, and sleep labs—demands solutions that are unobtrusive, privacy-preserving, and robust to static reflections, multipath, and inter-subject interference. This paper presents a complete millimetre-wave frequency-modulated continuous-wave (FMCW) technology - multiple-input multiple-output (MIMO) radar framework for multi-subject vital-sign sensing with three key contributions: (i) clutter-robust target discovery to stabilize detections in realistic indoor scenes; (ii) high-resolution spatial separation to suppress inter-subject leakage; and (iii) hybrid time–frequency decomposition to improve heartbeat isolation by mitigating respiration harmonics and noise. Experiments on single-, two-, and three-subject datasets achieve Mean Absolute Error/ Root Mean Squared Error (MAE/RMSE) of 2.81/4.13 Beats Per Minute (BPM) for respiration and 2.43/3.61 BPM for heart rate. Compared with filtering-, Ensemble Empirical Mode Decomposition (EEMD), Compressive Sensing - Orthogonal Matching Pursuit (CS-OMP), and mmRH-Millimetre-wave radar heart-rate (mmRH) based baselines, the proposed framework yields substantially lower heart-rate errors while maintaining reliable multi-subject operation in shared indoor environments.

References

【1】
【1】
 
 
Electronic Research Archive
Pages 1477-1505

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Lai D, Cai Z, Tian G, et al. Robust multi-person vital-sign sensing in indoor environments using FMCW MIMO radar. Electronic Research Archive, 2026, 34(3): 1477-1505. https://doi.org/10.3934/era.2026067

334

Views

10

Downloads

0

Crossref

0

Web of Science

1

Scopus

Received: 14 November 2025
Revised: 21 January 2026
Accepted: 27 January 2026
Published: 12 February 2026
©2026 the Author(s), licensee AIMS Press.

This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0)