AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home AIMS Energy Article
PDF (827.3 KB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Open Access

Experimental investigation of the effect of TDS on the thermal performance of the different types of solar stills

Hind I. El-Refaey1( )Saleh. M. Shalaby2Swellam W. Sharshir3Hewida Omara1Tamer A. Gado1
Irrigation and Hydraulics Engineering Department, Faculty of Engineering, Tanta University, Tanta 31511, Egypt
Engineering Physics and Mathematics Department, Faculty of Engineering, Tanta University, Tanta, 31511, Egypt
Mechanical Engineering Department, Faculty of Engineering, Kafrelsheikh University, Kafrelsheikh 33516, Egypt
Show Author Information

Abstract

In regions with a restricted availability of drinkable water, solar stills offer a solution for a passive solar desalination method. In this study, three designs for solar stills are examined: the conventional solar still (CSS), the hemispheric solar still (HSS), and the pyramidal solar still (PSS). The experimental investigations were conducted over three consecutive days, thereby varying the total dissolved solids (TDS) concentrations in the basin water at 1000, 2000, and 3000 ppm. A comparative analysis focused on the performance of the various solar stills and the impact of TDS variation. The results revealed that the PSS consistently outperformed the CSS and HSS across all TDS levels. Notably, the PSS exhibited superior daily energy and exergy efficiencies. Furthermore, the daily productivity and energy efficiencies displayed an inverse relationship with the TDS concentration. A cost analysis indicated that the PSS achieved the lowest distilled water price, reaching a value of 0.0151 $/L. Specifically, the PSS exhibited a 17.3% and 3.5% higher accumulated daily productivity compared to CSS and HSS, respectively, at TDS = 1000. However, at TDS = 3000, the daily productivity of the PSS decreased by 3.5% and 7.5% compared to TDS = 2000 and 1000, respectively. Similarly, the energy efficiency of the PSS decreased by 5.27% and 8.67% as the TDS increased from 1000 to 3000. Notably, across all solar still types, the lowest cost values were consistently associated with the lowest TDS concentrations, with the PSS yielding the lowest cost overall.

References

【1】
【1】
 
 
AIMS Energy
Pages 428-448

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
El-Refaey HI, Shalaby SM, Sharshir SW, et al. Experimental investigation of the effect of TDS on the thermal performance of the different types of solar stills. AIMS Energy, 2025, 13(2): 428-448. https://doi.org/10.3934/energy.2025016

9

Views

0

Downloads

1

Crossref

0

Web of Science

1

Scopus

Received: 10 November 2024
Revised: 16 March 2025
Accepted: 25 March 2025
Published: 15 April 2025
©2025 the Author(s), licensee AIMS Press.

This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0)