Original Research | Open Access

The Value of VTTQ Combined with B-mode US for Distinguishing Benign from Malignant Breast Masses by Comparing with SE: A Clinical Research

Lujing LiaZuofeng Xua( )
Department of Ultrasound, the Seventh Affiliated Hospital of Sun Yat-sen University, Shenzhen, Guangdong, China
Show Author Information

Abstract

Objective

The purpose of this study was to compare the diagnostic performance of virtual touch tissue quantification (VTTQ) combined with B-mode ultrasonograpgy (US), strain elastography (SE) combined with B-mode US and B-mode US alone in differentiating the properties of breast lesions.

Methods

A retrospective database was queried for 283 healthy subjects and 100 consecutive patients with 130 breast lesions. All the cases were examined by B-mode US, VTTQ and SE. Histological diagnosis was used as the reference standard. The area under the receiver operating curve (AUC) values of each data set was compared.

Results

Twenty-two lesions were determined as malignant and 108 as benign. The best cutoff point of VTTQ was 7.82 m/s. The AUC of B-mode US combined with VTTQ or SE was greater than that of B-mode US alone (0.913 or 0.918 vs. 0.797) (P = 0.007 and 0.012).

Conclusion

Both VTTQ and SE could give help to B-mode US in distinguishing benign from malignant breast lesions about elastography values. There was no difference between them.

References

【1】
【1】
 
 
Advanced Ultrasound in Diagnosis and Therapy
Pages 394-400

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Li L, Xu Z. The Value of VTTQ Combined with B-mode US for Distinguishing Benign from Malignant Breast Masses by Comparing with SE: A Clinical Research. Advanced Ultrasound in Diagnosis and Therapy, 2023, 7(4): 394-400. https://doi.org/10.37015/AUDT.2023.220041

782

Views

149

Downloads

0

Crossref

0

Scopus

Received: 15 November 2022
Revised: 15 February 2023
Accepted: 21 March 2023
Published: 30 December 2023
© AUDT 2023

This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license, which permits unrestricted use, distribution and reproduction in any medium provided that the original work is properly attributed.