AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Article | Open Access

Numerical Investigation of CO2 Contaminant Transport and Deposition in an In-Line Pulse Tube Cryocooler

Hao Zhu1,2Xi Chen1,2( )Pengcheng Qu1,2Yifan Zhu1,2Haoyi Wang1,2Yingxia Qi1,2
School of Energy and Power Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai, China
Shanghai Key Laboratory of Multiphase Flow and Heat Transfer in Power Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai, China
Show Author Information

Abstract

Pulse tube cryocoolers are widely employed in cryogenic systems, where gas contamination has become a critical factor limiting both performance and service life. To further investigate the condensation behavior of contaminants, this study develops a two-dimensional axisymmetric model of a linear-type cryocooler to simulate the transport and deposition processes of trace CO2, evaluating the impact of contamination on system pressure drop under various operating conditions. Results indicate that CO2 diffusion is primarily driven by concentration gradients. The CO2 deposition rate increases markedly at low temperatures and high concentrations, with over 90% of deposition occurring in the cold-end heat exchanger. Under different concentration distributions, dry ice predominantly accumulates in the cold-end heat exchanger; however, notable differences emerge in the pulse tube. In the uniform distribution case, CO2 tends to deposit along the inner wall of the pulse tube, whereas in the gradual release scenario, deposition mainly occurs on the cold-end flow straightening mesh screen. Dry ice deposition significantly increases the pressure drop across the system and decreases the pressure wave amplitude, resulting in a degradation of cooling capacity. This study lays a foundation for further investigation into the thermal properties of contaminant layers and provides theoretical guidance for optimizing cold-end components to improve contamination resilience.

References

【1】
【1】
 
 
Frontiers in Heat and Mass Transfer
Article number: 3

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zhu H, Chen X, Qu P, et al. Numerical Investigation of CO2 Contaminant Transport and Deposition in an In-Line Pulse Tube Cryocooler. Frontiers in Heat and Mass Transfer, 2026, 24(1): 3. https://doi.org/10.32604/fhmt.2026.076127

1

Views

0

Downloads

0

Crossref

0

Web of Science

0

Scopus

Received: 14 November 2025
Accepted: 06 January 2026
Published: 28 February 2026
© The Author 2026.

This work is licensed under a Creative Commons Attribution 4.0 International License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.