AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (996.8 KB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Article | Open Access

Modeling and Experimental Study of an Open Two-Phase Loop Driven by Osmotic Pressure and Capillary Force

Hanli Bi1Zheng Peng2Chenpeng Liu3Zhichao Jia1Guoguang Li1Yuandong Guo2Hongxing Zhang1( )Jianyin Miao1
National Key Laboratory of Spacecraft Thermal Control, Beijing Institute of Spacecraft System Engineering, China Academy of Space Technology, Beijing, 100094, China
School of Aeronautical Science and Engineering, Beihang University, Beijing, 100083, China
School of Energy and Environment Engineering, University of Science and Technology Beijing, Beijing, 100083, China
Show Author Information

Abstract

As space technology advances, thermal control systems must effectively collect and dissipate heat from distributed, multi-source environments. Loop heat pipe is a highly reliable two-phase heat transfer component, but it has several limitations when addressing multi-source heat dissipation. Inspired by the transport and heat dissipation system of plants, large trees achieve stable and efficient liquid supply under the influence of two driving forces: capillary force during transpiration in the leaves (pull) and root pressure generated by osmotic pressure in the roots (push). The root pressure provides an effective liquid supply with a driving force exceeding 2 MPa, far greater than the driving force in conventional capillary-pumped two-phase loops. Research has shown that osmotic heat pipes offer a powerful driving force, and combining osmotic pressure with capillary force has significant advantages. Therefore, this paper designs a multi-evaporator, dual-drive two-phase loop, using both osmotic pressure and capillary force to solve the multi-source heat dissipation challenge. First, a transmembrane water flux model for the osmotic pressure-driven device was established to predict the maximum heat transfer capacity of the dual-drive two-phase loop. Then, an experimental setup for a multi-evaporator “osmotic pressure + capillary force” dual-drive two-phase loop was constructed, capable of transferring at least 235 W of power under a reverse gravity condition of 20 m. The study also analyzed the effects of reverse gravity height, heat load distribution among the three evaporators, startup sequence, and varying branch resistances on the performance of the dual-drive two-phase loop.

References

【1】
【1】
 
 
Frontiers in Heat and Mass Transfer
Pages 55-70

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Bi H, Peng Z, Liu C, et al. Modeling and Experimental Study of an Open Two-Phase Loop Driven by Osmotic Pressure and Capillary Force. Frontiers in Heat and Mass Transfer, 2025, 23(1): 55-70. https://doi.org/10.32604/fhmt.2024.057933

1071

Views

75

Downloads

3

Crossref

2

Web of Science

2

Scopus

Received: 31 August 2024
Accepted: 07 November 2024
Published: 26 February 2025
© The Author 2024.

This work is licensed under a Creative Commons Attribution 4.0 International License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.