AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.9 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Article | Open Access

An Experimental and Numerical Thermal Flow Analysis in a Solar Air Collector with Different Delta Wing Height Ratios

Ghobad Shafiei Sabet1( )Ali Sari1Ahmad Fakhari2( )Nasrin Afsarimanesh3Dominic Organ4Seyed Mehran Hoseini1
Department of Mechanical Engineering Shahrood Branch, lslamic Azad University, Shahrood, Iran
Airflow Sciences Corporation, Livonia, MI, USA
School of Civil and Mechanical Engineering, Curtin University, Bentley, Australia
Department of English as an Additional Language (EAL), Heriot-Watt University, Galashiels, Scotland
Show Author Information

Abstract

This study conducts both numerical and empirical assessments of thermal transfer and fluid flow characteristics in a Solar Air Collector (SAC) using a Delta Wing Vortex Generator (DWVG), and the effects of different height ratios (Rh = 0.6, 0.8, 1, 1.2 and 1.4) in delta wing vortex generators, which were not considered in the earlier studies, are investigated. Energy and exergy analyses are performed to gain maximum efficiency. The Reynolds number based on the outlet velocity and hydraulic diameter falls between 4400 and 22000, corresponding to the volume flow rate of 5.21–26.07 m3/h. It is observed that the delta wing vortex generators with a higher height ratio yield maximum heat transfer enhancement and overall enhancement ratio. The empirical and numerical findings demonstrate that the exergy and thermal efficiencies decline in a specific range. The Nusselt number, pressure drop, energy, and exergy efficiencies enhance with rising Reynolds number, although the friction coefficient diminishes. The maximum heat transfer enhancement is 57%. According to the evaluation of exergy efficiency, the greatest efficiency of 31.2% is obtained at Rh = 1.4 and Reynolds number 22000.

References

【1】
【1】
 
 
Frontiers in Heat and Mass Transfer
Pages 491-509

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Sabet GS, Sari A, Fakhari A, et al. An Experimental and Numerical Thermal Flow Analysis in a Solar Air Collector with Different Delta Wing Height Ratios. Frontiers in Heat and Mass Transfer, 2024, 22(2): 491-509. https://doi.org/10.32604/fhmt.2024.048290

312

Views

34

Downloads

4

Crossref

8

Web of Science

9

Scopus

Received: 04 December 2023
Accepted: 29 January 2024
Published: 30 April 2024
© The Author 2024.

This work is licensed under a Creative Commons Attribution 4.0 International License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.