Article | Open Access

Impact of the Inlet Flow Angle and Outlet Placement on the Indoor Air Quality

Ikram Mostefa Tounsi1( )Mustapha Boussoufi1Amina Sabeur1Mohammed El Ganaoui2
Laboratoire des Sciences et Ingénierie Maritimes, Faculté de Génie Mécanique. Université des Sciences et de la Technologie d’Oran Mohammed Boudiaf, BP 1505 El M’Naouer, Oran, 31000, Algérie
Laboratoire LERMAB IUT Longwy, Université de Lorraine, Nancy, 54000, France
Show Author Information

Abstract

This study aims to optimize the influence of the inlet inclination angle on the Indoor Air Quality (IAQ), heat, and temperature distribution in mixed convection within a two-dimensional square cavity filled with an air-CO2 mixture. The air-CO2 mixture enters the cavity through two inlet openings positioned at the top wall, which is set at the ambient temperature (TC). Three values of the Reynolds numbers, ranging from 1000 to 2000, are considered, while the Prandtl number is kept constant (Pr = 0.71). The temperature distribution and streamlines are shown for Rayleigh number (Ra) equal to 104, three inlet inclination angles ϕ (0, π/6 and π/4) and three CO2 concentrations values (1500, 2500, 3500 ppm) applied at both hot vertical walls (maintained at a constant temperature TH). A finite volume method is used under the assumption of two-dimensional laminar flow to solve the Navier-Stokes and energy equations. The results indicate that inlet inclination angle has an impact on the indoor air quality (IAQ), which, in turn, affects the heat transfer distribution and thermal comfort within the cavity.

References

【1】
【1】
 
 
Fluid Dynamics & Materials Processing
Pages 2603-2616

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Tounsi IM, Boussoufi M, Sabeur A, et al. Impact of the Inlet Flow Angle and Outlet Placement on the Indoor Air Quality. Fluid Dynamics & Materials Processing, 2024, 20(11): 2603-2616. https://doi.org/10.32604/fdmp.2024.050641

386

Views

45

Downloads

1

Crossref

1

Web of Science

1

Scopus

Received: 12 February 2024
Accepted: 11 July 2024
Published: 30 November 2024
© The Author 2024.

This work is licensed under a Creative Commons Attribution 4.0 International License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.