AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (11.8 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Article | Open Access

Hybrid CNN Architecture for Hot Spot Detection in Photovoltaic Panels Using Fast R-CNN and GoogleNet

Carlos Quiterio Gómez Muñoz1Fausto Pedro García Márquez2( )Jorge Bernabé Sanjuán3
HCTLab Research Group, Electronics and Communications Technology Department, Universidad Autónoma de Madrid, Madrid, 28049, Spain
Ingenium Research Group, Universidad de Castilla-La Mancha, Ciudad Real, 13071, Spain
Department of Engineering, School of Architecture, Engineering and Design, Universidad Europea de Madrid, Villaviciosa de Odon, 28670, Spain
Show Author Information

Abstract

Due to the continuous increase in global energy demand, photovoltaic solar energy generation and associated maintenance requirements have significantly expanded. One critical maintenance challenge in photovoltaic installations is detecting hot spots, localized overheating defects in solar cells that drastically reduce efficiency and can lead to permanent damage. Traditional methods for detecting these defects rely on manual inspections using thermal imaging, which are costly, labor-intensive, and impractical for large-scale installations. This research introduces an automated hybrid system based on two specialized convolutional neural networks deployed in a cascaded architecture. The first convolutional neural network efficiently detects and isolates individual solar panels from high-resolution aerial thermal images captured by drones. Subsequently, a second, more advanced convolutional neural network accurately classifies each isolated panel as either defective or healthy, effectively distinguishing genuine thermal anomalies from false positives caused by reflections or glare. Experimental validation on a real-world dataset comprising thousands of thermal images yielded exceptional accuracy, significantly reducing inspection time, costs, and the likelihood of false defect detections. This proposed system enhances the reliability and efficiency of photovoltaic plant inspections, thus contributing to improved operational performance and economic viability.

References

【1】
【1】
 
 
Computer Modeling in Engineering & Sciences
Pages 3369-3386

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Gómez Muñoz CQ, Márquez FPG, Sanjuán JB. Hybrid CNN Architecture for Hot Spot Detection in Photovoltaic Panels Using Fast R-CNN and GoogleNet. Computer Modeling in Engineering & Sciences, 2025, 144(3): 3369-3386. https://doi.org/10.32604/cmes.2025.069225

241

Views

3

Downloads

3

Crossref

1

Web of Science

4

Scopus

Received: 18 June 2025
Accepted: 11 August 2025
Published: 30 September 2025
© The Author 2024.

This work is licensed under a Creative Commons Attribution 4.0 International License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.