AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (17.7 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Article | Open Access

Evaluation of ASM for Ventricular Segmentation in Patients with Diverse Cardiac Abnormalities

Oskar Kapuśniak1Adam Piórkowski2( )Julia Lasek3Karolina Nurzyńska4
Faculty of Electrical Engineering, Automatics, Computer Science and Biomedical Engineering, AGH University of Krakow, Kraków, Poland
Department of Biocybernetics and Biomedical Engineering, AGH University of Krakow, Kraków, Poland
Faculty of Geology, Geophysics and Environmental Protection, AGH University of Krakow, Kraków, Poland
Department of Algorithmics and Software, Silesian University of Technology, Gliwice, Poland
Show Author Information

Abstract

The efficacy of Active Shape Models (ASM) for automated ventricular segmentation was evaluated to address the computational demands of manual segmentation and the interpretability limitations of deep learning. A statistical shape model was constructed using a limited cohort of 19 Coronary Computed Tomography Angiography (CCTA) scans derived from patients with diverse cardiac abnormalities. Principal Component Analysis (PCA) was employed to encapsulate morphological variability, and strict point correspondence was enforced to maintain topological consistency. Validation was conducted via leave-one-out cross-validation, benchmarking automated segmentations against expert-delineated ground truths using the Dice Similarity Coefficient (DSC) and Hausdorff Distance (HD). It was found that mean Dice scores ranged from 0.50 to 0.64, with individual high-fidelity cases achieving scores up to 0.84. These results indicated that while quantitative performance reflected the complexity of pathological morphology, the methodology successfully accommodated high morphometric variance. It can be concluded that the ASM framework provides a resilient, interpretable foundation for managing complex clinical geometry where unconstrained models may fail.

References

【1】
【1】
 
 
Computers, Materials & Continua

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Kapuśniak O, Piórkowski A, Lasek J, et al. Evaluation of ASM for Ventricular Segmentation in Patients with Diverse Cardiac Abnormalities. Computers, Materials & Continua, 2026, 87(3). https://doi.org/10.32604/cmc.2026.076062

5

Views

0

Downloads

0

Crossref

0

Web of Science

0

Scopus

Received: 13 November 2025
Accepted: 06 March 2026
Published: 09 April 2026
© The Author 2026.

This work is licensed under a Creative Commons Attribution 4.0 International License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.