AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Article | Open Access

Nonlinear Registration of Brain Magnetic Resonance Images with Cross Constraints of Intensity and Structure

Han Zhou1,2Hongtao Xu1,2Xinyue Chang1,2Wei Zhang1,2Heng Dong1,2( )
Digital Fujian Research Institute of Big Data for Agriculture and Forestry, Fujian Agriculture and Forestry University, Fuzhou, 350002, China
College of Computer and Information Science, Fujian Agriculture and Forestry University, Fuzhou, 350002, China
Show Author Information

Abstract

Many deep learning-based registration methods rely on a single-stream encoder-decoder network for computing deformation fields between 3D volumes. However, these methods often lack constraint information and overlook semantic consistency, limiting their performance. To address these issues, we present a novel approach for medical image registration called the Dual-VoxelMorph, featuring a dual-channel cross-constraint network. This innovative network utilizes both intensity and segmentation images, which share identical semantic information and feature representations. Two encoder-decoder structures calculate deformation fields for intensity and segmentation images, as generated by the dual-channel cross-constraint network. This design facilitates bidirectional communication between grayscale and segmentation information, enabling the model to better learn the corresponding grayscale and segmentation details of the same anatomical structures. To ensure semantic and directional consistency, we introduce constraints and apply the cosine similarity function to enhance semantic consistency. Evaluation on four public datasets demonstrates superior performance compared to the baseline method, achieving Dice scores of 79.9%, 64.5%, 69.9%, and 63.5% for OASIS-1, OASIS-3, LPBA40, and ADNI, respectively.

References

【1】
【1】
 
 
Computers, Materials & Continua
Pages 2295-2313

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zhou H, Xu H, Chang X, et al. Nonlinear Registration of Brain Magnetic Resonance Images with Cross Constraints of Intensity and Structure. Computers, Materials & Continua, 2024, 79(2): 2295-2313. https://doi.org/10.32604/cmc.2024.047754

218

Views

3

Downloads

1

Crossref

1

Web of Science

1

Scopus

Received: 16 November 2023
Accepted: 04 March 2024
Published: 31 May 2024
© The Author 2024.

This work is licensed under a Creative Commons Attribution 4.0 International License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.