AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (5.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Open Access | Just Accepted

MedRev: Reversing Negative Transfer in Medical Multi-modal Foundation Model Fine-tuning for Improved Medical Image Analysis

Yuncheng Jiang1, Chun-Mei Feng2, Jiankun Hu1, Lusheng Wang3, Le Zhang4( )

1 Department of General Surgery, Gastric Cancer Center & Laboratory of Gastric Cancer, State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu, 610041, China

2 School of Computer Science, University College Dublin, D04 V1W8, Ireland

3 Department of Computer Science, CityUniversity of Hong Kong, 999077, Hong Kong, China

4 College of Computer Science, Sichuan University, Chengdu, 610065, China

Show Author Information

Abstract

Medical multi-modal foundation models (MFMs) have shown strong generalization potential for smart clinical applications. However, conflicting cross-modal priors can cause them to underperform single-modal foundation models on specific downstream tasks. We define this phenomenon as “negative multi-modal transfer”, where the transfer gain of a multi-modal backbone becomes inconsistent or negative for a target modality. Through controlled experiments, we observe that (1) the extent of pretraining and (2) which layers are selected for fine-tuning substantially affect whether knowledge transfers effectively across modalities in downstream tasks. To address this, we propose MedRev, an efficient fine-tuning paradigm developed to reverse the negative transfer effect in medical foundation models. MedRev introduces a mixture-of-pre-trained experts strategy that adaptively lever-ages knowledge from different pre-trained checkpoints based on downstream data. Moreover, a dynamic layer freezing strategy is employed to decrease unnecessary updates and fine-tune those most beneficial for the target modality. Extensive experiments on downstream datasets across ten modalities demonstrate that MedRev consistently mitigates the negative transfer and increases fine-tuning performance.

References

【1】
【1】
 
 
Tsinghua Science and Technology

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Jiang Y, Feng C-M, Hu J, et al. MedRev: Reversing Negative Transfer in Medical Multi-modal Foundation Model Fine-tuning for Improved Medical Image Analysis. Tsinghua Science and Technology, 2026, https://doi.org/10.26599/TST.2026.9010095

251

Views

20

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 24 April 2026
Revised: 18 June 2026
Accepted: 30 September 2026
Available online: 30 September 2026

© The author(s) 2026.

The articles published in this open access journal are distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/).