AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (11.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Enhancing Power Line Insulator Health Monitoring with a Hybrid Generative Adversarial Network and YOLO3 Solution

Department of Electronics and Communication Engineering, Koneru Lakshmaiah Education Foundation, Hyderabad 500075, India
Department of Electrical and Electronics Engineering, National Institute of Technology Nagaland, Dimapur 797103, India
Show Author Information

Abstract

In the critical field of electrical grid maintenance, ensuring the integrity of power line insulators is a primary concern. This study introduces an innovative approach for monitoring the condition of insulators using aerial surveillance via drone-mounted cameras. The proposed method is a composite deep learning framework that integrates the “You Only Look Once” version 3 (YOLO3) model with deep convolutional generative adversarial networks (DCGAN) and super-resolution generative adversarial networks (SRGAN). The YOLO3 model excels in rapidly and accurately detecting insulators, a vital step in assessing their health. Its effectiveness in distinguishing insulators against complex backgrounds enables prompt detection of defects, essential for proactive maintenance. This rapid detection is enhanced by DCGAN’s precise classification and SRGAN’s image quality improvement, addressing challenges posed by low-resolution drone imagery. The framework’s performance was evaluated using metrics such as sensitivity, specificity, accuracy, localization accuracy, damage sensitivity, and false alarm rate. Results show that the SRGAN+DCGAN+YOLO3 model significantly outperforms existing methods, with a sensitivity of 98%, specificity of 94%, an overall accuracy of 95.6%, localization accuracy of 90%, damage sensitivity of 92%, and a reduced false alarm rate of 8%. This advanced hybrid approach not only improves the detection and classification of insulator conditions but also contributes substantially to the maintenance and health of power line insulators, thus ensuring the reliability of the electrical power grid.

References

【1】
【1】
 
 
Tsinghua Science and Technology
Pages 1796-1809

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Akella R, Gunturi SK, Sarkar D. Enhancing Power Line Insulator Health Monitoring with a Hybrid Generative Adversarial Network and YOLO3 Solution. Tsinghua Science and Technology, 2024, 29(6): 1796-1809. https://doi.org/10.26599/TST.2023.9010137

1399

Views

135

Downloads

16

Crossref

12

Web of Science

18

Scopus

0

CSCD

Received: 20 August 2023
Revised: 14 December 2023
Accepted: 26 December 2023
Published: 20 June 2024
© The Author(s) 2024.

The articles published in this open access journal are distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/).