AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

A Computer-Aided System for Ocular Myasthenia Gravis Diagnosis

Faculty of Information Technology, Beijing University of Technology, Beijing 100124, China
Neurology Department, The Second Affiliated Hospital of Tsinghua University, Beijing 100040, China
Department of Automation, Tsinghua University, Beijing 100084, China
Show Author Information

Abstract

The current mode of clinical aided diagnosis of Ocular Myasthenia Gravis (OMG) is time-consuming and laborious, and it lacks quantitative standards. An aided diagnostic system for OMG is proposed to solve this problem. The values calculated by the system include three clinical indicators: eyelid distance, sclera distance, and palpebra superior fatigability test time. For the first two indicators, the semantic segmentation method was used to extract the pathological features of the patient’s eye image and a semantic segmentation model was constructed. The patient eye image was divided into three regions: iris, sclera, and background. The indicators were calculated based on the position of the pixels in the segmentation mask. For the last indicator, a calculation method based on the Eyelid Aspect Ratio (EAR) is proposed; this method can better reflect the change of eyelid distance over time. The system was evaluated based on the collected patient data. The results show that the segmentation model achieves a mean Intersection-Over-Union (mIoU) value of 86.05%. The paired-sample T-test was used to compare the results obtained by the system and doctors, and the p values were all greater than 0.05. Thus, the system can reduce the cost of clinical diagnosis and has high application value.

References

【1】
【1】
 
 
Tsinghua Science and Technology
Pages 749-758

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Liu G, Wei Y, Xie Y, et al. A Computer-Aided System for Ocular Myasthenia Gravis Diagnosis. Tsinghua Science and Technology, 2021, 26(5): 749-758. https://doi.org/10.26599/TST.2021.9010025

2149

Views

279

Downloads

20

Crossref

17

Web of Science

23

Scopus

0

CSCD

Received: 27 February 2021
Accepted: 15 March 2021
Published: 20 April 2021
© The author(s) 2021

© The author(s) 2021. The articles published in this open access journal are distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/).