Discover the SciOpen Platform and Achieve Your Research Goals with Ease.
Search articles, authors, keywords, DOI, etc.
Based on single beam interference and general double beam interference holography experiments, this paper designs a hybrid double beam interference optical path with both reflection light and transmission light, and theoretically analyses the intensity distribution of interference superposition of two beams of object light and one beam of reference light on the holographic dry plate. Shooting holograms of single beam interference optical path with only reflector light, single beam interference optical path with only transmission light, and hybrid double beam interference optical path with both reflection light and transmission light, the imaging effects are compared and analyzed. The results show that the holograms taken by the optical path designed in this paper are more complete, clearer, and more hierarchical. Furthermore, different influencing factors are changed through the control variable method to improve the imaging quality of the hologram. After many experiments, the results show that when the GS-I holographic dry plates and a He-Ne laser with power of about 2.23mW and wavelength of 632.8nm are used to take the hologram, the exposure time is controlled to be 15s, the angle between the reflector object light and the reference light is 25 °~35 °, the angle between the transmission object light and the reference light is 20 °~30 °, and the light intensity ratio of the reflector object light, the transmission object light and the reference light is about 1∶1∶1, the overall imaging effect of the hologram is the best.
Comments on this article