AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (4.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Open Access | Just Accepted

3D-printed flexible piezoelectric scaffolds restore load-bearing function of regenerated bone

Suyun Li1,§, Yanbo Shan2,§, Yixuan Wang1, Zengqin Shi1, Yifeng Dong1, Lisheng Zhao2( ), Rujie He1,3( ), Ying Li1,3( )

1 Institute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, China

2 Institute of Stomatology & Oral Maxilla Facial Key Laboratory, First Medical Center of Chinese PLA General Hospital, Beijing 100853, China

3 Marine Science and Technology Domain, Beijing Institute of Technology, Zhuhai 519088, China

§ Suyun Li and Yanbo Shan contributed equally to this work.

Show Author Information

Abstract

Flexible piezoelectric scaffolds can conform to irregular bone defects and deliver wireless electrical stimulation, yet whether their mechanical and electrical functions persist throughout the months-long course of bone remodeling, as well as whether the regenerated bone ultimately recovers load-bearing function, remains unresolved. Here, we report PUA/BTO/β-TCP elastomer–ceramic piezoelectric scaffolds fabricated by digital light processing (DLP) into a triply periodic minimal surface (TPMS) architecture. Calcination of BTO increased its ferroelectric tetragonal phase content and enhanced the piezoelectric coefficient d33 of the composites by up to 44.3%. The scaffolds combined full elastic recovery after 50% compression with durable mechanoelectrical performance: after 28 days of immersion in simulated body fluid, their quasi-static and cyclic mechanical properties remained essentially unchanged, and d33 remained above its initial value. Under ultrasound excitation, the scaffolds significantly enhanced osteoblast proliferation and osteogenic differentiation in vitro and accelerated femoral defect repair in rats, with the bone volume fraction reaching approximately 70% at 8 weeks, versus below 13% for controls. Critically, biomechanical testing at 8 weeks post-implantation showed that the repaired femur withstood a fracture limit load approximately 9.1% higher than that of intact native bone, survived cyclic compression at 70% of the limit load without detectable cracking, and exhibited crack arrest at the scaffold–bone interface, which was direct evidence of stable mechanical integration. We term the concurrent retention of mechanical resilience and piezoelectric output during remodeling, together with stable scaffold–bone mechanical integration, mechanoelectrical adaptation, and propose it as a design principle that shifts bone-scaffold development from short-term osteoinductivity toward sustained in vivo functionality.

Graphical Abstract

References

【1】
【1】
 
 
Nano Research

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Li S, Shan Y, Wang Y, et al. 3D-printed flexible piezoelectric scaffolds restore load-bearing function of regenerated bone. Nano Research, 2026, https://doi.org/10.26599/NR.2026.94909292

172

Views

16

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 17 August 2026
Revised: 15 October 2026
Accepted: 26 October 2026
Available online: 26 October 2026

© The Author(s) 2026. Published by Tsinghua University Press.

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, https://creativecommons.org/licenses/by/4.0/)